background image

16

17

MAINTENANCE

GENERAL

Care and cleaning of chrome and special finishes.

DO NOT

 use steel wool or cleansing agents containing alcohol, acid, abrasives, and 

alike. Use of any prohibited cleaning or maintenance products or substances could 

damage the surface of the soap dispenser or faucet.
For surface cleaning use ONLY soap and water, then wipe dry with a clean cloth or 

towel.
When cleaning bathroom tiles, the soap dispenser should be protected from any 

splattering of harsh cleansers.

FAUCET MAINTENANCE

FILTER CLEANING INSTRUCTIONS

This D28/TUBULAR/QUADRAT faucet is provided with a stainless steel filter preventing 

foreign particles to enter the lines. If the water flow has decreased, this may be because 

the filter is clogged. The filter can be cleaned as follows:
•  Shut-off the water shut off valve.
•  Disconnect the water supply pipe from the adaptor and disassemble the filter 

from it.

•  Wash the filter under running water.
•  Reassemble the parts.
•  Restore the incoming water supply.
•  Make sure that there is no water leakage.

SOLENOID VALVE SERVICING

The solenoid valve diaphragm requires periodical cleaning every six (6) month. The 

solenoid valve is located inside the Dual Power input box.
Remove the diaphragm from the solenoid valve and examine it for dirt. In case it is 

dirty or clogged, wash it under running water and reassemble it.
Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic 

solenoid valves.

SETTINGS ADJUSTMENT - FAUCET

DELAY IN TIME: It is recommended to change the delay in time for 

flush valves for urinals or toilets only. 

If required, the delay in time can also be modified in faucets as 

follows:
Press the IN button. Wait until a quick flashing of the LED in the 

sensor eye is perceived. Then, press + to increase the delay in 

time and – to reduce it.

DELAY OUT TIME: This button allows modifying the water flow 

time after the user removes his hands from the faucet. A delay out 

time close to 0 will save more water. An increased delay out time 

will make the user experience more comfortable.  

If required, the delay out time can be modified as follows:
Press the OUT button. Wait until a quick flashing of the LED in the 

sensor eye is perceived. Then, press + to increase the delay out 

time and – to reduce it.

24 HOUR HYGIENE FLUSH: This model includes a 24 hours hygiene 

flush which is disabled. To activate the hygiene flush, press the 

clock button. Wait until a quick flashing of the LED in the sensor eye 

is perceived. Then press + to activate the hygiene flush. To disable 

it again, press – to deactivate it. 

COMFORT FLUSH: If your model includes a Comfort flush setting, it 

can be activated by pressing the flush button. 
When the button is pressed, one blink of the LED in the sensor eye 

is perceived. The pre-programmed flush cycle will take place then.

The Comfort flush cannot be interrupted or deactivated by pressing 

any button until it is over.

TEMPORARY OFF FUNCTION: This function is ideal to perform any 

kind of activity in front of the sensor without operating the system 

(for example, cleaning). 

The faucet will remain shut for 1 minute when this button is 

pressed once. To cancel this function and to return to normal 

operation press the On/Off button again or wait 1 minute.

RESET BUTTON: This function restores all the factory settings 

except for the sensor range. If required, press the Reset button 

and without releasing it, press the + button once.

NOTE: 

To enter the self adjusting mode, use the ADJ button. To change the sensor 

range, use the RANGE button.

Summary of Contents for D28 500100

Page 1: ...1 INSTALLATION AND MAINTENANCE GUIDE INSTALLATION AND MAINTENANCE GUIDE D28 TUBULAR QUADRAT SOAP WATER KE SYSTEM D28 TUBULAR QUADRAT...

Page 2: ...re installing the faucet Do not allow dirt Teflon tape or metal particles to enter the faucet Shut off water supply when done Notes Cautions Cautions 1 PRE INSTALLATION 2 3 PACK CONTENTS 4 TECHNICAL D...

Page 3: ...VE OPTIONAL QTY QTY 1 1 SOAP BOTTLE SOAP BOTTLE AND BRACKET AND BRACKET QTY QTY 1 1 SCREW ANCHOR SCREW ANCHOR FOR SOAP BOTTLE FOR SOAP BOTTLE BRACKET BRACKET QTY QTY 2 2 DUAL POWER DUAL POWER INPUT BO...

Page 4: ...ng sensor Adjustable by remote control Sensor range soap dispenser 30 100 mm 10 mm Adjustable by remote control Soap capacity 1 Liter 33 8 oz Soap viscosity 100 3800 CPS Standard soap discharge 1 4 cc...

Page 5: ...ollowing parts will protrude out of the wall Faucet and Soap Dispenser bases with dust covers C1 NOTE It is recommended to fill the cavities around the base with cement to better secure it inside the...

Page 6: ...nd one water Inlet flexible tube The soap dispenser has two electrical wires and one soap inlet flexible tube and these wires and pipes will be connected at a later stage 7 Connecting the water supply...

Page 7: ...esting the System Important Note The D28 TUBULAR QUADRAT faucet and soap dispenser system include the self adjusting sensors The ideal sensor range for the specific location will be set automatically...

Page 8: ...t of the recommended range too close or too far will not operate The remote control can be used to adjust the following functions 1 SOAP QUANTITY The 1 4 drop keys allow the user to choose the desired...

Page 9: ...Wait until a quick flashing of the LED in the sensor eye is perceived Then press to increase the range and to reduce it Every push will increase or decrease one level Note Once you have changed the d...

Page 10: ...Press the IN button Wait until a quick flashing of the LED in the sensor eye is perceived Then press to increase the delay in time and to reduce it DELAY OUT TIME This button allows modifying the wat...

Page 11: ...e whether performed by a contractor service company or the consumer This warranty does not cover product damage caused by the following Incorrect installation inversions of supply pipes Pressures or t...

Page 12: ...the sensor does not flash once when user s hands are within the sensor s range No water is coming out of the faucet Decrease the range 2 Range is too long 3 Unit is in Security Mode Eliminate the caus...

Page 13: ...22 03 20 01500462 B 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com sternusa sternfaucets com...

Reviews: