background image

COBALT Pro

 Wall Sensor Retrofit Kit for

Exposed Flush Valve Installation Instructions

I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com

One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents

Part No. 101675

Flat Head Screwdriver

Phillips Screwdriver

T15H Screwdriver

Smooth Jaw 

Wrench

page 1

Rev 080323

• Sensor Cap Assembly
• ProLAST® T-Seal
• Actuator Opening Cover
• Wall Sensor
• Power & Interface Module

KIT INCLUDES

TOOLS NEEDED

Strap Wrench

• All plumbing should be installed according to applicable state 

and local codes and regulations. 

• Before installation of the I-CON flush valve, ensure the water 

closet or urinal fixture, drain line and water supply line are 

properly installed. 

• Water supply lines must be sized to allow for appropriate 

water flow for each fixture. 

• Flush all water supply lines of any debris before making 

connections. 

• Do not use pipe sealant or plumbing grease on any 

components or couplings, with the exception of the control stop 

inlet. 

• A smooth jaw or strap wrench should be used for installation 

to prevent damage to the finish of the I-CON flush valve and 

components. 

The I-CON flush valve is designed to operate at water pressures 

ranging from 15 to 100psi (103 to 689kPa). The fixture type 

determines the minimum pressure required for the valve. 

Most low-consumption water closets are designed to operate 

with a minimum flowing water pressure of 25psi (172kPa). 

Many building codes and the ASME A112.19.2 standard state 

maximum static water pressure as 80 psi. 

I-CON Systems, Inc. (I-CON) warrants that its commercial 

manufactured products are made of first-class materials, are 

free from defects, and are made to withstand normal use when 

installed properly. Products have the following warranty periods: 

3 years for COBALT®, COBALT Pro™, and COBALT Connect™ 

faucets and flush valves and I-CON EDGE® gateways. 1 year for 

all other products and decorative finishes. The warranty period 

begins on the date of purchase. 
Products should be sent to I-CON at the customer’s expense. 

I-CON will take a reasonable amount of time to determine if the 

product is defective and whether it will be repaired or replaced. 

During the warranty period, items will either be (1) repaired 

at no charge using new replacement parts or (2) replaced with 

either a new similar product or one manufactured from new or 

serviceable used parts are, at minimum, a functional equivalent 

to the original. The course of action will be determined at 

I-CON’s discretion. Replacement products that are installed 

according to the instructions provided by I-CON will assume the 

remaining warranty of the original product. The limited warranty 

is only applicable to the product’s materials and workmanship. 

No claims for labor, transportation, or other incidental or 

consequential costs will be allowed. No extended warranties 

are available. THE SOLE AND EXCLUSIVE REMEDY FOR ANY 

DEFECTIVE PRODUCT IS LIMITED TO REPAIRING OR REPLACING 

THE DEFECTIVE PRODUCT. Before installing and using products, 

the purchaser is responsible for determining the products’ 

suitability and assumes all risks and liabilities related to the 

product. 
This warranty only applies to persons and organizations that 

purchase I-CON products directly from I-CON or an authorized 

I-CON representative for the purpose of resale. This warranty 

does not apply to the life of batteries or other consumables.

PRIOR TO INSTALLATION

LIMITED WARRANTY

Summary of Contents for COBALT Pro 101675

Page 1: ...ommercial manufactured products are made of first class materials are free from defects and are made to withstand normal use when installed properly Products have the following warranty periods 3 year...

Page 2: ...x 4 x 4 x 2 1 2 The location will vary based on the rough in Refer to the rough in drawings for specific mounting location Use a GFCI plaster ring 4X4 JUNCTION BOX GFCI PLASTER RING I CON IR PLATE AN...

Page 3: ...com patents Part No 101675 page 3 Rev 080323 Step 5 Install actuator cover ProLAST T SEAL FLUSH VALVE CAP ASSEMBLY INSTALLATION Step 1 Insert ProLAST T Seal into flush valve body Step 2 Place square...

Page 4: ...rough junction box knock out Attach control module to junction box with provided screws Step 3 Reattach and secure cover with set screw WALL SENSOR INSTALLATION INSTALLATION WITHOUT ELECTRICAL BOX Ste...

Page 5: ...g out then up Step 4 Feed control module cable through 1 1 2 opening Attach control module to wall with provided screws Step 5 Reattach and secure face plate with set screw MOUNTING WALL FLANGE Step 1...

Page 6: ...eed the cable through the wall Step 4 Attach the wall flange to the wall using the screws provided Lock the conduit in place using the set screw on the wall flange INTERFACE MODULE INSTALLATION Step 1...

Page 7: ...ve after each adjustment The proper flow rate should completely cleanse fixture without splashing water outside of fixture NOTE The flow from the valve must never exceed the flow capacity of the fixtu...

Page 8: ...e quick action button Current profile number is displayed through LED illuminations and the digital display To change profile press and release profile quick action button again Continue to press and...

Page 9: ...ser The range can be adjusted from 6 54 inches Exit adjusts the amount of time an object must not be detected before the valve considers the user to have exited The range can be adjusted from 0 15 sec...

Reviews: