ADJUSTING CONTROL STOP
Step 1
Turn adjustment screw
COUNTERCLOCKWISE
1/2 turn from
closed position. Activate flush valve.
Step 2
To adjust flush valve, turn adjustment screw in small increments.
Activate flush valve after each adjustment. The proper flow rate
should completely cleanse fixture without splashing water
outside of fixture.
NOTE:
The flow from the valve must never exceed the flow
capacity of the fixture. If a valve failure should occur, the fixture
must be able to accommodate a continuous flow from the valve.
Step 3
Reinstall control stop cap.
CONTROL MODULE AND INTERFACE SETUP
NOTE:
When powered and face plate is removed, control module
automatically enters maintenance mode. While maintenance
mode is active, a solid green light indicates that a user is
detected. Control module exits maintenance mode when face
plate is replaced or after 30 minutes. To re-enter maintenance
mode, press any quick action button.
QUICK ACTION BUTTON DIAGRAM
Full Flush
Half Flush