background image

1

FELTON DIGITAL

INSTALLATION GUIDE

SMARTVIEW™

Digital Thermostatic Shower Mixer

FD-SVCSMC

Summary of Contents for SMARTVIEW FD-SVCSMC

Page 1: ...1 FELTON DIGITAL INSTALLATION GUIDE SMARTVIEW Digital Thermostatic Shower Mixer FD SVCSMC...

Page 2: ...2 SMARTVIEW INSTALL GUIDE...

Page 3: ...tallation 8 Operational test 19 Notice 5 Measurements 5 Tools required 6 Scope of application 7 TLC 30 FTD installation 9 Vision wheel interface final fit installation 14 Troubleshooting 20 Warranty 2...

Page 4: ...4 SMARTVIEW INSTALL GUIDE...

Page 5: ...out by qualified electrician Country specific standards and regulations do apply PRECAUTIONS 1 This appliance is not intended for use by persons including children with reduced physical sensory or me...

Page 6: ...body 3 In wall box 5 Set of screws 6x2 5x16mm 6 TLI W knob 1 TLC 30 FTD 3 Set of screws 2x5x50mm 2 Back Up Battery 4 Connecting adapter 2 Vision wheel black white 4 Fastening seal Kit silicone seal b...

Page 7: ...area Important The TLC 30 FTD must be accessible and should not be sealed in the wall Cable length 6m max Hot in Cold in TLC 30 FTD Handset xed head outlets VISION WHEEL INTEFACE Note The vision wheel...

Page 8: ...meter hole is required in a fixing nog flush with face of the timber framing Conduits should be used in the walls where necessary to protect the cables and allow maintenance Attach the in wall box usi...

Page 9: ...TLC 30 FTD INSTALLATION Wire not supplied Conduit not supplied The draw wire should be fitted before the wall is lined NOTE Feeding a string or wire through the in wall box and conduit will make it e...

Page 10: ...GUIDE 15V ACCU EXT RS 232 MOTOR TLI AUX Outlet HOT COLD Inlets Fixing holes Cover retaining holes Connector block Power supply Battery compartment 1 2 Connects to hand shower 1 Connects to fixed head...

Page 11: ...le and dry Use the processor template on the last page to mark the position of the fixing holes in the selected location ORIENTATION FOR WALL SITUATION MOUNTING OPTIONS MOUNTING FOR CONCRETE 1 Install...

Page 12: ...T L I A U X Fully insert the inlet adapter into the inlet valves one long and one short adapter 8 Connect hot and cold water supply IMPORTANT Flush the pipework before connection A B Connect hot and...

Page 13: ...tlet adapters and connect outlet pipeworks Primary outlet Hand Shower Secondary outlet Fixed Head 1 2 If using two outlets Connect outlet and outlet 1 2 If only using single outlet Outlet to be connec...

Page 14: ...m diameter holes should be drilled in the tile etc to finish Draw a line around the collar flush with the wall Cut down the collar as marked Final wall lining Final wall lining 12 Tighten adapter reta...

Page 15: ...he TLI W body Feed data cable through silicone seal and black foam seal Secure both cables to the previously installed draw wire and pull the cables to the TLC 30 FTD 60mm 5mm 40mm 56mm 60mm 110mm Ste...

Page 16: ...LI W body into the vision wheel interface and lock by turning clockwise 2 Fit knob 3 16 Position vision wheel interface and attach in screws 1 Push and twist to lock ADVICE Push in firmly Fit silicone...

Page 17: ...UX Place back up battery in shown location within TLC 30 FTD and connect cable to ACCU port Note After installation battery may require 24 hours of charging on mains power before battery back up funct...

Page 18: ...IMPORTANT Electrical supply must be installed by a qualified electrician 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 21 Re fit cover and connect TLC 30 FTD to the mains 20 Connect vision wheel...

Page 19: ...ower supply The installed system should be operated to check for leaks 2 Open Push the Smartview Interface once The TLC 30 FTD unit opens and the LED illuminates 3 Close Push the Smartview Interface a...

Page 20: ...hot water Check hot water tank and instantaneous connections Temperature sensor defect Carry out function Self Check Diagnosis on Smartview User Guide Difference in supply pressure between hot and co...

Page 21: ...uring defects only and does not cover any damage to product due to abuse negligence or improper installation This warranty is given on the understanding that the product is installed by a registered p...

Page 22: ...22 SMARTVIEW INSTALL GUIDE...

Page 23: ...23 FELTON DIGITAL 8 x 55 8 x 55 this side up this side up 235mm SMARTVIEW PROCESSOR TEMPLATE...

Page 24: ...INSTALL GUIDE felton industries limited FeltonIndustriesLimited feltonltd feltonltd feltontapware FELTON INDUSTRIES LTD 8 Farmhouse Lane Glen Innes Auckland 1072 sales felton co nz Find us on Social M...