background image

12

13

FILLING THE SOAP TANK

SETTINGS ADJUSTMENT - SOAP DISPENSER

1

Unscrew the soap tank from the pump assembly and 

pull it out of the bottle support.

2

Fill in the liquid soap up to the top lin

e.

3

Insert the bottle inside the bottle support.

4

Screw the soap tank back to the pump assembly. Make 

sure the tank is firmly secured into place.

5

Press the refill button located at the back of the pump 

assembly until soap starts coming out of the soap 

dispenser spout. This operation can also be done 

using the soap dispenser remote control Refill function. 

6

NOTE

: Once the soap in the soap tank has reached the 

bottom line the soap tank should be refilled. To refill 

the soap tank please refer to steps 1-5.

If you acquired the remote control together with your soap dispenser, you may adjust 

the dispenser settings if required. To use the remote control hold it straight in front 

of the sensor at a distance of about 10-15 cm (4-6”).
Attention: The remote control held out of the recommended range (too close or too 

far) will not operate.
The remote control can be used to adjust the following functions:

  1-SOAP QUANTITY

The 1-4 drop keys allow the user to choose the desired soap quantity. 

4

2.1 to 2.3 *

3

1.6 to 1.9 

2

1.2 to 1.6

1

0.7 to 0.9

Indication: continuous blinking of the LED light in the sensor eye.

2

3

1

4

  2-ADJ

This function resets the sensor back to factory 

settings.  

Indication: 2 blinks of the LED light in the sensor 

eye.

  

3-TEMPORARY OFF FUNCTION

This  function is ideal to perform any kind of 

activity in front of the sensor without operating 

the system (for example, cleaning).  The soap 

dispenser will remain shut for one minute when 

this button is pressed once.  

To cancel this function and to return to normal 

operation press the On/Off button again or wait 

for one minute.
Indication: OFF – 2 fast blinks, ON – 4 fast blinks

 

 

4-FILL THE SOAP TANK

Once the soap tank has been filled / re-filled, 

press the FILL button. The pump will run for 

one minute for priming the soap to the soap 

dispenser spout. 
To stop this activity press the FILL button again. 

If the soap has not started coming out of the 

spout, press the Fill button again.

Summary of Contents for D28 500100

Page 1: ...1 INSTALLATION AND MAINTENANCE GUIDE INSTALLATION AND MAINTENANCE GUIDE D28 TUBULAR QUADRAT SOAP WATER KE SYSTEM D28 TUBULAR QUADRAT...

Page 2: ...re installing the faucet Do not allow dirt Teflon tape or metal particles to enter the faucet Shut off water supply when done Notes Cautions Cautions 1 PRE INSTALLATION 2 3 PACK CONTENTS 4 TECHNICAL D...

Page 3: ...VE OPTIONAL QTY QTY 1 1 SOAP BOTTLE SOAP BOTTLE AND BRACKET AND BRACKET QTY QTY 1 1 SCREW ANCHOR SCREW ANCHOR FOR SOAP BOTTLE FOR SOAP BOTTLE BRACKET BRACKET QTY QTY 2 2 DUAL POWER DUAL POWER INPUT BO...

Page 4: ...ng sensor Adjustable by remote control Sensor range soap dispenser 30 100 mm 10 mm Adjustable by remote control Soap capacity 1 Liter 33 8 oz Soap viscosity 100 3800 CPS Standard soap discharge 1 4 cc...

Page 5: ...ollowing parts will protrude out of the wall Faucet and Soap Dispenser bases with dust covers C1 NOTE It is recommended to fill the cavities around the base with cement to better secure it inside the...

Page 6: ...nd one water Inlet flexible tube The soap dispenser has two electrical wires and one soap inlet flexible tube and these wires and pipes will be connected at a later stage 7 Connecting the water supply...

Page 7: ...esting the System Important Note The D28 TUBULAR QUADRAT faucet and soap dispenser system include the self adjusting sensors The ideal sensor range for the specific location will be set automatically...

Page 8: ...t of the recommended range too close or too far will not operate The remote control can be used to adjust the following functions 1 SOAP QUANTITY The 1 4 drop keys allow the user to choose the desired...

Page 9: ...Wait until a quick flashing of the LED in the sensor eye is perceived Then press to increase the range and to reduce it Every push will increase or decrease one level Note Once you have changed the d...

Page 10: ...Press the IN button Wait until a quick flashing of the LED in the sensor eye is perceived Then press to increase the delay in time and to reduce it DELAY OUT TIME This button allows modifying the wat...

Page 11: ...e whether performed by a contractor service company or the consumer This warranty does not cover product damage caused by the following Incorrect installation inversions of supply pipes Pressures or t...

Page 12: ...the sensor does not flash once when user s hands are within the sensor s range No water is coming out of the faucet Decrease the range 2 Range is too long 3 Unit is in Security Mode Eliminate the caus...

Page 13: ...22 03 20 01500462 B 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com sternusa sternfaucets com...