1) Automatic activation (default setting).
This is the mode most people will use
. The product comes
with the auto and ignition linked together. This means that there
are no external activation requirements for the product. When
the input voltage goes above 13.3V (alternator or battery
charger is working) then the unit will simply engage and boost
the output. When the input voltage drops below 13.0V but above
12.2V the unit shall remain on (boost) for another 120 seconds.
If the input voltage remains between 12.2V and 13.0V for more
than 120 seconds the unit shall go into sleep mode. If the input
voltage drops below 12.2V within this 120 second time frame the
unit shall immediately go into sleep. If input voltage is then to rise
immediately to between 12.2V and 13.0V the 120 second timer
shall continue. To get out of sleep mode an input voltage of
13.3V+ must be reached. To reset the 120 second timer the
input voltage must exceed 13.6V for over 5 seconds. If this
threshold is not met then sleep mode would resume
immediately if the voltage drops below 13V again.
This mode complements Regen. Braking / Smart Alts.
+
+
+
Auto
Ignition
Low V
regen. braking
Link
+
+
+
Auto
Low V
regen. braking
To Ignition feed*
+
+
+
Auto
Low V
To Ignition feed*
Link
(optional)
2) Ignition feed activation (with automatic on/off)
This mode is a basic ignition feed. There is no 120 second timer.
When you have a live ignition feed (~12V). The unit simply
activates when the input voltage is 13.3V+. It shall then enter
sleep mode if the input voltage drops below 13.2V. If live feed is
turned off the unit enters sleep. To turn unit on again, turn on live
feed and ensure input voltage is above 13.3V+, there will be a 10
second delay.
When you would use this feature?
If the starter and house bank are connected via a voltage sensitive
relay (as well as this charger) whereby a high voltage (13.3V) is
relayed from the house bank back to the starter bank this charger
shall remain on, thus, ultimately depleting both batteries.
This mode does not complement Regen. Braking / Smart
Alternator.
Unit operational mode
Standby, sleep and off modes
Standby
- only happens when
in ignition mode, when the
ignition is off and the input
voltage is above 13.3V. Blue
LED flashes continually and 4x
green LEDS are lit. To get out of
standby turn ignition on and
ensure above 13.3V on the
input.
Sleep
- the unit goes into sleep mode
when a low input voltage threshold has
been breached. This varies between
functions. Typically, when the input
voltage drops below 13.0V the unit
enters sleep mode after a 120 second
delay. The blue LED flashes once for
10ms every 60 seconds.
Off
- to remove power
from unit completely
remove negative or
positive input cable.
There is no 'off' function
per se
. Removing power
will not
reset the settings
on the charger.
Page 7
R.B.F
R
egenerative
raking riendly
B
F
R.B.F
R
egenerative
raking riendly
B
F
1) Automatic activation (default
setting)
automatically on at 13.3V.
Off 120 seconds after input voltage
drops below 13.0V and above 12.2V.
S l e e p m o d e d e a c t i v a t e s a t
13.3V+.120 second timer reactivates
at 13.6V+ for 5 seconds.
2) Ign
ition Feed Activation.
With live feed
(~12V) the unit turns on at 13.3V+ input
voltage. Goes into sleep when below 13.2V.
When live feed is removed the unit enters
sleep. Unit turns on again when live feed is re-
established and input voltage is 13.3V+ (there
is a 10 second delay).
1) Automatic activation (default setting).
The product comes with the auto and ignition linked together. This
means that there are no external activation requirements for the product.
When the input voltage goes above 13.3V (alternator or battery charger
is working) then the unit will simply engage and boost the output. When
the input voltage drops below 13.0V but above 12.2V the unit shall
remain on (boost) for another 120 seconds. If the input voltage remains
between 12.2V and 13.0V for more than 120 seconds the unit shall go
into sleep mode. If the input voltage drops below 12.2V within this 120
second time frame the unit shall immediately go into sleep. If input
voltage is then to rise immediately to between 12.2V and 13.0V the 120
second timer shall continue. To get out of sleep mode an input voltage of
13.3V+ must be reached. To reset the 120 second timer the input voltage
must exceed 13.3V for over 5 seconds. If this threshold is not met then
sleep mode would resume immediately if the voltage drops below 13V
again.
This mode complements Regen. Braking / Smart Alts.
+
+
+
Auto
Ignition
Low V
regen. braking
Link
+
+
+
Auto
Low V
regen. braking
To Ignition feed*
+
+
+
Auto
Low V
regen. braking
To Ignition feed*
Link
3) Re enerative raking Ignition feed activation
g
b
.
Simply requires live ignition to charge. If ignition is
off then charger turns off.
2) Ignition feed activation (with automatic on/off)
This mode is a basic ignition feed. There is no 120 second timer. When you
have a live ignition feed (~12V). The unit simply activates when the input
voltage is 13.3V+. It shall then enter sleep mode if the input voltage drops
below 13.2V. If live feed is turned off the unit enters sleep. To turn unit on
again, turn on live feed and ensure input voltage is above 13.3V+, there will
be a 10 second delay.
When you would use this feature?
If the starter and house bank are connected via a voltage sensitive relay (as
well as this charger) whereby a high voltage (13.3V) is relayed from the
house bank back to the starter bank this charger shall remain on, thus,
ultimately depleting both batteries.
This mode does not complement Regen. Braking / Smart Alternator.
BBW updated operational modes.
1) Automatic activation (default setting)
automatically on at 13.3V. Off 120 seconds after
input voltage drops below 13.0V and above 12.2V.
Sleep mode deactivates at 13.3V+.120 second timer
reactivates at 13.3V+ for 5 seconds
2) Ign
ition Feed Activation.
With live feed (~12V)
the unit turns on at 13.3V+ input voltage. Goes into
sleep when below 13.2V. When live feed is removed
the unit enters sleep. Unit turns on again when live
feed is re-established and input voltage is 13.3V+
(there is a 10 second delay).
(optional)
3) Pure ignition feed mode - WARNING potential flat battery.
IDEALLY SUITED FOR EURO 6+ VEHICLES.
If your starter battery does not climb above 13V when you turn the engine on
and you wish to utilise the capability of the charger when stationary you shall
need to apply an ignition feed to the depicted connector.
This is pure ignition feed mode. If you have a live ignition feed then the BBW shall start
to charge. When the ignition signal turns off then the charger stops charging and goes
to sleep. This mode complements Regen. It shall work down to 10V input. This mode
is ideal for those vehicles that start up and the alternator is switched off and the starter
battery’s voltage is not high enough to trigger the BBW to switch on.
The link can be added if you want all the functions of mode 1 when the ignition is
turned off. Perhaps you are running a battery charger to charge up your starter battery
and want the BBW to turn on to charge the auxiliary battery without having to have the
ignition on.
This mode complements Regen. Braking / Smart Alts.
WARNING - This mode could potentially drain battery if ignition is left on
without the engine running.
EURO 6+
Best suited for Euro 6+