Sterling Power Products
Copyright
Sterling Power Products
H Charge
Float
In / Unit
Out / Rem
Batt.
V
12.2
Temp
Menu
Change
Volts
Select
Audible alarm on/off
hold > 3 sec
On / Off
hold>3 sec
Fault
Absorption
Cond.
Setup - Menu:
“bPc”
“btY”
„Cbt“
“coU”
“IoU”
“C/F”
“boS”
“CL”
“buC”
“ASc”
“con”
“bLc”
“bLt”
“br9”
“b9b”
“LEd”
“uId”
“uSW”
“rSW”
“Loc”
“rSt”
* =
only possible
if not locked
Remote Control
The home screen displays the output voltage from the unit.
If ‘crc’ is displayed at any point, simply ignore, continue as you
were, all this mean is that the remote has received a corrupt
readout signal from the charger (merely momentary).
Please
note, for 24V only operations you setup as 12V. I.e. if you want
to set a voltage, for example, 26V you set in the parameters
for 13V.
Remote Buttons: Left Button (Volts Select). Press button for
output voltage. Press button again for remote sense voltage. If
remote sense voltage cable is not connected then the display is
0.0V (with a red backlight). Press button again to revert back to
home screen input voltage. Hold button for 4 seconds to set
alarm to ‘off’, repeat procedure to turn alarm to ‘on’.
Right Button (Temp Menu Setup). Press button for unit
temperature. Press button again for battery temperature (via batt
temp sensor). If sensor is not attached then the reading shall be
nc
(non compliant). Press again to view unit temperature.
To access the menu and adjust parameters:
To access the menu and adjust the parameters press and hold the
right button (Temp Menu Setup) until
SEL
appears (approximately
5 seconds), then let go.
bPc
shall appear and you can now scroll
through all of the 18 parameters unidirectional using the right
button only. You can enter whichever parameter you wish by
pressing the left button (Volts Select). Certain parameters are
adjustable, the majority are, however, just a read out. Refer to the
chart below.
To exit from the menu, holding down both left and right buttons
simultaneously will result in END appearing on the screen. This
shall ultimately revert back to the home screen.
“bPc”
display boost current in percent.
displays battery profile type (0-9). This number denotes which charging profile the
“btY”
charger is set to. (Ref: table labelled ‘Battery Chemistry Selection’ on).
Custom battery type profile. Check special instructions how to set up.
“Cbt”
displays cut off voltage (the voltage at which the unit stops boosting) (13.4V)
“CoU”
display input / output base voltage (12/24V).
“IoU”
change from celcius to fahrenheit or back (default = celcius). Press right button to
“C/F”
*
change between Fahrenheit (FAH) and Celsius (cEL).
“boS”
Boost voltage half / full toggle. “HI” means full, toggle to “Low” means half.
“CL”
Current limit level adjust. 100 = 100% (default max) 90 = 90%, 80 = 80% ....-> 30 = 30%.
“buC”
turn Buzzer on / off (default = on). Left button for
off
and right button for
on.
*
Autoscroll on / off (default = off). Left button for
off
and right button for
on.
“Asc”
change contrast value from 0 to 7 (default = 3). Left button
down
and right button
up.
“con”
*
change backlight colour . off <- auto -> green -> red -> blue (default = auto). To change
“bLc”
*
right button goes from
off ---> blue
and left button goes
blue ---> off
.
change backlight time . 1 - 600 seconds, 0 = always on, (default = 60). Right button
“bLt”
*
goes up the values, left button goes down the values. Hold button to accelerate.
change voltage from red to green backlight 8.0V - 13.3V (default 12.4V). Press right
“br9”
*
button to increase value, press left button to decrease value. Hold to accelerate.
change voltage from green to blue backlight 12.4V - 16.0V (default 13.4V). Press right
“b9b”
*
button to increase value, press left button to decrease value. Hold to accelerate.
change LED on time 1 - 600 seconds, 0 = always on, (default = 60). Press right button
“LEd”
to increase in value, press left to decrease in value. Hold button to accelerate.
display Unit ID.
“uId”
display unit software version.
“uSW”
display remote software version.
“rSW”
Lock unit lock code = 1 to 999 (default = unlocked).
WARNING
This mode shall lock
“Loc”
the unit by virtue of a pass code, be careful. Press right button to increase value, press left
button to decrease value. Please release button when on the number you require, the software
shall store this number, then the display shall read:
loc
-> on -> #. # = number you have
stored. To remove
loc
, return to
loc
and re-enter the number, release buttons and the display
should read:
loc
-> off (green backlight).
Please make a note of this loc code here:_______
.
Reset to default values*. Left button NO, right button YES. Let go when on YES to reset.
“rSt”
only possible if not locked.
* =
SEL
To eject from menu simply do nothing for 10 sec it will jump out
6
7
5
1
2
3
4
8
9
Volts Select Button
Quick guide:
Quick press = back light on.
Short hold = switch between
voltages you want to select
long press switch buzzer on/off
(temporary).
(more detailed information
below)
Temp Menu Change button
Quick press = back light on.
Short hold = switch between
temperatures.
Long press = Menu + setup +
sel display
Remote control:
cut hole diameter
54mm
Page 11
Provided the remote is connected,
all modifications made to the
battery charger (not the remote)
from the remote control shall be
stored and saved, even if power is
cut to the charger. However, when
the remote is disconnected these
modifications shall be reset to
default.
Remote Error Codes
E00
= high input voltage
E01
= high output voltage
E02
= high unit temp
E03
= high batt. temp
E04
= no output voltage