75
Appendix C: Wave Utilities
© 2017 Stenograph
c. Write a stroke on the steno machine.
d. In the TrueView dialog box, select
Connect Realtime
. The Save As dialog box displays.
Navigate to where you want to save the realtime file. Type a file name and select
Save
.
3. The selected file displays with the steno note file in the middle column and the TrueStroke data, in
Compact view, in the right column.
Vertical Notes with TrueStroke Data in Compact View
4. Double click the TrueStroke data column to toggle the view, from Compact to Expanded. Expanded
view shows the TrueStroke details for each stroke. The details reveal the timing, direction of travel,
depressed or released, and velocity of the steno keys in a stroke. See
Understanding the TrueStroke
Data
on page 76 for more information on data interpretation.
TrueStroke Data in Expanded View
5. Additional TrueView features allow you to search, zoom, modify the font and print the TrueStroke
data. See
TrueView Menu Features
on page 78 for feature details.