DOCUMENT NUMBER:
L500-912.820 ISSUE JUL 20, 2016
AMENDMENT: 00
DATE: --
CHAPTER-
PAGE 3-55
MAINTENANCE MANUAL STEMME S12
3.7.18.4
TRANSFER PUMP CONTROL AND TANK SELECTION
The transfer pumps are powered by the engine electrical system. They transfer pumps are con-
trolled by a float switch in the feeder tank and by a pump selector switch. At feeder tank fuel levels
below 90% the transfer pump control is active. The pilot selects the pump on a rotary switch with
the positions LEFT-BOTH-RIGHT. Due to the check valves downstream from the transfer pumps,
the related tank outlet will be closed off completely when the associated transfer pump is not
powered. Thus the pump selector switch functions as a tank selector.
The selected transfer pump/pumps stops automatically when the fuel level reaches 90% in the
feeder tank. On feeder tank-fuel level below 90% the selected transfer pump/pumps start auto-
matically.
The transfer pumps can be activated manually by a test push-button in the cockpit center console
when the Master Switch is ON. This function is used for daily inspection or Maintenance Tasks.
The transfer pump/pumps to be tested can be selected by using the fuel selector switch (Left,
Right, Both).
3.7.19 FUEL QUANTITY INDICATION (ATA 28-40-00)
3.7.19.1
DESCRIPTION
A float type fuel level sender is installed in each fuel tank in the wing. The electrical resistance of
the sender changes depending on the float position. This resistance is measured and displayed
to the pilot on one pointer-type fuel level indicator for each tank. The indicator scale is marked
with lines, each representing one eighth of full.
A separate float type switch is installed in the feeder tank which activates a yellow low fuel warn-
ing light on the instrument panel at feeder tank fuel levels below ca. 2.5 ltr.
The fuses for the fuel level indicator system are located in the instrument panel fuse holder (en-
gine bus).
3.7.19.2
PARTS SPECIFICATION
Part
STEMME p/n
Manufacturer p/n
Fuel Quantity Indicator
831.435
UMA T18112F1F4, TSO
Fuel Level Sender
851.503
VDO 226 801 015 001 G, modified
3.7.19.3
OPERATION
The fuel quantity indication system does not require any operation actions by the pilot.
Instructions to the pilot in case of low fuel level situation can be found in the AFM.
Summary of Contents for S12
Page 1: ......
Page 3: ......
Page 97: ......
Page 238: ......
Page 240: ......
Page 242: ......
Page 244: ......
Page 246: ......
Page 248: ......
Page 250: ......
Page 255: ...A FLIGHT CONTROLS PITCH CONTROL AND TRIM ...
Page 256: ......
Page 257: ...B FLIGHT CONTROLS LATERAL CONTROL WING FLAP AILERON ...
Page 258: ......
Page 259: ...C FLIGHT CONTROLS AIRBRAKE CONTROL ...
Page 260: ......
Page 261: ...D FLIGHT CONTROLS RUDDER CONTROL ...
Page 262: ......
Page 263: ......
Page 264: ......
Page 265: ...E PROPULSION SYSTEM ...
Page 266: ......
Page 268: ......
Page 270: ......
Page 272: ......
Page 274: ......
Page 276: ......
Page 278: ......
Page 280: ......
Page 282: ......
Page 284: ......
Page 286: ......
Page 288: ......
Page 290: ......