108
14
May 2021, SmartScanNG² User's Guide for Wayside Enclosure Components, EUD-2018086-00 Rev.3
Before the shutters are opened, if you get a signal level greater than 200 millivolts, it
usually means that there is noise on the scanner inputs, which most times is caused by
an electrical problem with the scanner. If you cannot isolate and fix the cause of this
problem, call STC for help.
Auto Calibration Selected
Signal levels in millivolts with closed shutters
Rail1
Rail2
Wheel1
Wheel2
Min/Max/Average
Min/Max/Average
Min/Max/Average
Min/Max/Average
210 250
210
0
60
20
0
60
20
20
80
40
•
•
•
Before the shutters are closed, if you don't get a calibrated temperature in the range of
178°F to 182°F, it means that the scanner wasn't calibrated. If cleaning the optics
doesn't solve your problem, replace the scanner cover-and-module assembly. If this
doesn't solve your problem, call STC for help in fixing the problem.
14
When "Auto-Calibration Disengaged" is displayed on your computer, remove the
calibrated heat source.
15
Take the calibrated heat source to the bearing scanner on the south or west rail.
16
With the power cord to the rear of the scanner, place the calibrated heat source on the
bearing scanner.
Scanner
Type III
Cable
Heat Source
17
Repeat steps
14
through
15
.
18
To return to the Main menu, type
X
19
To exit the serial interface and return the system to normal operation, type
X
20
If this is a double-track site, repeat steps
1
through
20
for the second track.
Summary of Contents for Smartscan NG2
Page 6: ...6 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Page 10: ...10 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Page 42: ...42 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Page 48: ...48 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Page 50: ...50 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Page 56: ...56 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Page 68: ...68 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Page 94: ...94 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...