Procedure:
3
2
1
4
M A X .
M I N .
6
2
IMGT3992
-
Check the oil level.
Note :
The oil level in the tank (1) of the pump (4) must be within the limits indicated on
the label on the tank.
The oil can be topped up by unscrewing the cap (3).
ATTENTION
A decrease in this level is an indication that there is an anomaly in the system.
If the oil level drops again after topping it up, the problem but be addressed.
ATTENTION
Only the oils indicated in the table below can be used for the cam motion's hydraulic
circuit.
OIL
Recommended
MOBIL DTE 25
Viscosity 46 to 40°C
6 - Maintenance
1781 B1 DRC10
© Stäubli 2013 – F.143.489.04-C