48 of 86
Analog outputs 1 to 4
The following table shows the parameters of analog output 1 to be set. Identical
setting possibilities apply to analog outputs 2 to 4 (for WRX900/04 analog outputs
3 and 4).
Parameters
Display
bottom
line
Display
top
line
Value range/Selection
Output signal
type
A1.Mod
0-20
4-20
0-10
(0 to 20) mA
(4 to 20) mA
(0 to 10) V
Output source
(Analog
selector)
A1.SEL
1
0
1 to 16
17 to 20
no analog value
Actual value channel 1
to 16
Modbus remote control
values analog 1 to 4
Zero point
A1.Zer
-30
-9999 to +9999
End point
A1.End
+260
-9999 to +9999
Error
behavior
A1.Err
ErLo
ErHi
negative signals:
<-0.1 mA/<3.6 mA/< -0.1 V
positive signals:
> 21 mA/> 21 mA/> 10.5 V
(depending on the output signal type)