STANDARD SANDBLASTER - TABLE 1A

  

 

INPUT 

APPROX. 

 

 

 

 

 

 

GAS 

VENT 

 

 

        CONNECTIONS 

Approximate 

 

 

RATE 

TANK 

 

 

 

 

 

 

INLET 

 

DIA 

 

 

INLET 

 

 

OUTLET 

              Ship. Weight

  MODEL 

BTU/Hr. 

CAP. 

 

TOP  FRONT  BACK  TOP  FRONT  BACK  STD. 

ASME

SBD71120  120,000 BTU/Hr.  71 Gal  69.75”  4.25”  59.50” 

50.87”  19.69” 

19” 

1/2”  51.88” 

6” 

27.75”  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  400 Lbs 

NA

 

 

35 kW/Hr 

268 L 

177 cm  11 cm  151 cm  129 cm  50 cm  48 cm  1/2”  132 cm  15 cm  71 cm  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  182 Kg 

NA

SBD81154  154,000 BTU/Hr  81 Gal  73.00”  4.25”  66.50” 

57.87”  19.69” 

19” 

1/2”  59.00” 

6” 

27.75”  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  470 Lbs 

NA

 

 

45 kW/Hr 

307 L 

185 cm  11 cm  169 cm  147 cm  50 cm  48 cm  1/2”  150 cm  15 cm  71 cm  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  213 Kg 

NA

SBD81180  180,000 BTU/Hr  81Gal 

67.50”  4.50”  62.00” 

53.62”  20.50” 

21” 

1/2”  54.62” 

6” 

27.75”  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  470 Lbs 

NA

 

 

53 kW/Hr 

307 L 

171 cm  12 cm  157 cm  136 cm  52 cm  53 cm  1/2”  139 cm  15 cm  71 cm  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  213 Kg 

NA

SBD100199* 199,000 BTR/Hr  100 Gal  75.00”  4.50”  70.00” 

61.62”  20.50” 

21” 

1/2”  62.62” 

6” 

27.75”  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  603 Lbs 

NA

 

 

58 kW/Hr 

379 L 

192 cm  12 cm  178 cm  157 cm  52 cm  53 cm  1/2”  159 cm  15 cm  71 cm  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  273 Kg 

NA

SBD100199 199,000 BTU/Hr.  100 Gal  75.00”  4.50”  70.00” 

61.62”  20.50” 

21” 

1/2”  61.50” 

6” 

27.75”  1.50”  1.50” 

2.00”  1.50”  1.50”  2.00”  603 Lbs 

NA

 

 

58 kW/Hr 

379 L 

192 cm  12 cm  178 cm  157 cm  52 cm  53 cm  1/2”  150 cm  15 cm  71 cm  1.50”  1.50” 

2.00”  1.50”  1.50”  2.00”  273 Kg 

NA

SBD81199  199,000 BTUH  81 Gal 

67.50”  4.50”  62.00” 

53.62”  20.50” 

21” 

1/2”  54.62” 

6” 

27.75”  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  470 Lbs 

NA

 

 

58 kW/hr 

307 L 

171 cm  12 cm  157 cm  136 cm  52 cm  53 cm  1/2”  139 cm  15 cm  71 cm  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  213 Kg 

NA

SBD100199** 199,000 BTR/Hr  100 Gal  72.00”  4.50”  65.13” 

55.87”  19.75” 

23” 

1/2”  56.38” 

6” 

30.25”  1.50”  2.00” 

2.00”  1.50”  2.00”  2.00”  630 Lbs 

725 Lbs

 

 

58 kW/Hr 

379 L 

183 cm  12 cm  165 cm  142 cm  50 cm  58 cm  1/2”  143 cm  15 cm  77 cm  1.50”  2.00” 

2.00”  1.50”  2.00”  2.00”  286 Kg 

329 Kg

SBD100250 250,000 BTR/Hr  100 Gal  72.00”  4.50”  65.13” 

55.87”  19.75” 

23” 

1/2”  56.38” 

8” 

30.25”  1.50”  2.00” 

2.00”  1.50”  2.00”  2.00”  630 Lbs 

725 Lbs

 

 

72 kW/Hr 

379 L 

183 cm  12 cm  165 cm  142 cm  50 cm  58 cm  1/2”  143 cm  20 cm  77 cm  1.50”  2.00” 

2.00”  1.50”  2.00”  2.00”  286 Kg 

329 Kg

SBD65251  251,000 BTR/Hr  65 Gal  75.00”  4.50”  65.75” 

57.25”  20.00” 

NA 

1/2” 

58.75 

8” 

27.75” 

NA 

1.50” 

1.50”  NA 

1.50”  1.50”  750Lbs 

862 Lbs

 

 

73 kW/Hr 

246 L 

191 cm  12 cm  167 cm  145 cm  51 cm 

NA 

1/2”  149 cm  20 cm  70 cm 

NA 

1.50” 

1.50”  NA 

1.50”  1.50”  341 Kg 

391 Kg

SBD100275 275,000 BTR/Hr  100 Gal  72.00”  4.50”  65.13” 

55.87”  19.75” 

23” 

1/2”  56.38” 

8” 

30.25”  1.50”  2.00” 

2.00”  1.50”  2.00”  2.00”  630 Lbs 

725 Lbs

 

 

80 kW/Hr 

379 L 

183 cm  12 cm  165 cm  142 cm  50 cm  58 cm  1/2”  143 cm  20 cm  77 cm  1.50”  2.00” 

2.00”  1.50”  2.00”  2.00”  286 Kg 

329 Kg

SBD65305  305,000 BTR/Hr  65 Gal  75.00”  4.50”  65.75” 

57.25”  20.00” 

NA 

1/2” 

58.75 

8” 

27.75” 

NA 

1.50” 

1.50”  NA 

1.50”  1.50”  750 Lbs 

862 Lbs

 

 

89 kW/Hr 

246 L 

191 cm  12 cm  167 cm  145 cm  51 cm 

NA 

1/2”  149 cm  20 cm  70 cm 

NA 

1.50” 

1.50”  NA 

1.50”  1.50”  341 Kg 

391 Kg

SBD85365  365,000 BTR/Hr  85 Gal  79.50”  4.50”  70.25” 

62.50”  22.50” 

23” 

3/4” 

63.00 

8” 

27.75”  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  725 Lbs 

833 Lbs

 

 

107 kW/Hr 

322 L 

202 cm  12 cm  178 cm  159 cm  57 cm  58 cm  3/4”  160 cm  20 cm  70 cm  1.50”  1.50” 

1.50”  1.50”  1.50”  1.50”  329 Kg 

379 Kg

SBD100390  390,000 BTUH  100 Gal  75.50”  4.50”  67.50” 

58.25”  26.75” 

23” 

3/4”  59.00” 

8” 

30.25”  1.50”  2.00” 

2.00”  1.50”  2.00”  2.00”  760 Lbs 

874 Lbs

 

 

114 kW/Hr 

379 L 

192 cm  12 cm  171 cm  148 cm  68 cm  58 cm  3/4”  150 cm  20 cm  77 cm  1.50”  2.00” 

2.00”  1.50”  2.00”  2.00”  345 Kg 

396 Kg

  * Tall model.

 ** Short model.

TABLE 1B - HEATER PERFORMANCE DATA SBD MODELS

 

 

INPUT 

APPROX.   

 

 

 RECOVERY RATING CAPACITIES (GPH AND LPH)

 

 

RATE 

GAL 

EFF.  30° F  40° F  50° F  60° F  70° F  80° F  90° F  100° F  110° F  120° F  130° F  140° F

  MODEL 

BTUH 

CAP. 

%  (-)1° C  4° C  10° C  15° C  21° C  27° C  32° C  38° C  43° C  49° C  54° C  60° C

 SBD71120 

120,000 BTUH  71 Gal 

80 

388 

291 

233 

194 

166  145 

129 

116 

106 

97 

90 

83 

 

 

35 kW/Hr 

268 L 

 

1469  1102 

882 

734 

628  549 

488 

439 

401 

367 

341 

314

 SBD81154 

154,000  BTUH  81 Gal 

80 

498 

373 

299 

249 

213  187 

166 

149 

136 

124 

115 

107

 

 

45 kW/Hr 

306 L 

 

1885  1412  1132 

943 

806  708 

628 

564 

515 

469 

435 

405

 SBD81180 

180,000 BTUH  81 Gal 

80 

579 

434 

347 

289 

248  217 

193 

174 

158 

145 

134 

124

 

 

53 kW/Hr 

306L 

 

2192  1643  1314  1094 

939  821 

731 

659 

598 

549 

507 

469

 SBD100199*  199,000 BTUH  100 Gal  80 

643 

482 

386 

322 

276  241 

214 

193 

175 

161 

148 

132

 

 

58 kW/Hr 

379 L 

 

2434  1825  1461  1219  1045  912 

810 

731 

662 

609 

560 

500

 SBD100199  199,000 BTUH  100 Gal  80 

643 

482 

386 

322 

276  241 

214 

193 

175 

161 

148 

132

 

 

58 kW/Hr 

379L 

 

2434  1825  1461  1219  1045  912 

810 

731 

662 

609 

560 

500

 SBD81199 

199,000 BTUH  81 Gal 

80 

614 

461 

368 

307 

263  230 

205 

184 

167 

154 

142 

132

 

 

58 kW/Hr 

306 L 

 

2324  1745  1393  1162 

996  871 

776 

697 

632 

583 

538 

500

 SBD100199** 199,000 BTUH  100 Gal  80 

643 

482 

386 

322 

276  241 

214 

193 

175 

161 

148 

132

 

 

58 kW/Hr 

379 L 

 

2434  1825  1461  1219  1045  912 

810 

731 

662 

609 

560 

500

 SBD100250  250,000 BTUH  100 Gal  80 

808 

606 

485 

404 

346  303 

269 

242 

220 

202 

186 

173

 

 

73 kW/Hr 

379 L 

 

3059  2294  1835  1529  1311  1147  1020 

918 

834 

765 

706 

655

 SBD65251 

251,000 BTUH  65 Gal 

80 

811 

608 

487 

406 

348  304 

270 

243 

221 

203 

187 

174

 

 

73 kW/Hr 

246 L 

 

3071  2303  1843  1536  1316  1152  1024 

921 

838 

768 

709 

658

SBD100275  275,000 BTUH  100 Gal  80 

889 

667 

533 

444 

381  333 

296 

267 

242 

222 

205 

190

 

 

80 kW/Hr 

379 L 

 

3365  2524  2019  1682  1442  1262  1122  1009 

918 

841 

776 

721

 SBD65305 

305,000 BTUH  65 Gal 

80 

986 

739 

592 

493 

423  370 

329 

296 

269 

246 

228 

211

 

 

89 kW/Hr 

246 L 

 

3732  2799  2239  1866  1599  1399  1244  1120  1018 

933 

861 

800

 SBD85365 

365,000 

85 Gal 

80 

1180 

885 

708 

590 

506  442 

393 

354 

322 

295 

272 

253

 

 

107 kW/Hr 

322 L 

 

4466  3349  2680  2233  1914  1675  1489  1340  1218  1116  1031 

957

 SBD100390  390,000 BTUH  100 Gal  80 

1293 

970 

776 

646 

554  485 

431 

388 

353 

323 

298 

277

 

 

114 kW/Hr 

379 L 

 

4894  3671  2936  2447  2097  1835  1631  1468  1335  1224  1129  1049

 

*  Tall models.

  **  Short models.

Summary of Contents for SBD100199*

Page 1: ...FERENCE CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE Thank you for buying this energy efficien...

Page 2: ...FIGURE 1 ROUGH IN DIMENSIONS See Tables 1A and 1B SBD71120 models are approved for 5 13 cm venting using a 6 15 cm to 5 13 cm reducer...

Page 3: ...5 NA 1 50 1 50 NA 1 50 1 50 750 Lbs 862 Lbs 89 kW Hr 246 L 191 cm 12 cm 167 cm 145 cm 51 cm NA 1 2 149 cm 20 cm 70 cm NA 1 50 1 50 NA 1 50 1 50 341 Kg 391 Kg SBD85365 365 000 BTR Hr 85 Gal 79 50 4 50...

Page 4: ...89 kWh 365 000 107 kWh 399 000 117 kWh and 500 000 147 kWh Btuh with a recovery rating of 277 3 gph 1049 Lph or more also comply with ANSI Z21 10 3 as an automatic instantaneous type heater Detailed...

Page 5: ...such as having a cold or diminishing sense of smell with age For these reasons the use of a propane gas detector is recommended IF YOU EXPERIENCE AN OUT OF GAS SITUATION DO NOT TRYTO RELIGHTAPPLIANCE...

Page 6: ...cannon must be oriented correctly for proper function There is a marked range on the pipe nipple portion of the hydro cannon that must be aligned with the top of the inlet spud A label above the jacke...

Page 7: ...d with commercial water heaters Although circulators are oiled and operated by the manufacturer some circulators must be oiled again before operating Please refer to manufacturer s instructions DISHWA...

Page 8: ...t least 2 5cm deep with length and width at least 2 5cm greater than the diameter of the heater and must be piped to an adequate drain The pan must not restrict combustion air flow For appliance insta...

Page 9: ...insulation caulking vapor barrier etc air for combustion ventilation and draft hood dilution must be obtained from outdoors The installation instructions for confined spaces in tightly constructed bui...

Page 10: ...ere will be a minimum of turbulence inside the heater If a water heater is installed in a closed water system contact the water supplier or local plumbing inspector on how to control this situation WA...

Page 11: ...0 197 198 199 200 Input 180 000 190 000 199 000 Btuh Total Vent Height Feet Draft Hood 6 6 8 10 15 20 30 50 100 Input Btuh Rise Vent Connector Diameter in inches 180 000 1 Ft 8 8 8 8 8 7 7 7 190 000 8...

Page 12: ...10 10 8 8 8 Number of Combined Input Heaters in Thousands of Btuh Manifold Common Vent Diameter 2 610 14 14 12 12 12 10 10 10 3 915 16 16 16 14 14 12 12 12 4 1220 18 18 16 16 16 14 14 12 MODEL 365 40...

Page 13: ...0 60 66 138 260 530 810 1520 2400 4300 8800 70 61 125 240 490 750 1400 2250 3900 8100 80 57 118 220 460 690 1300 2050 3700 7500 90 53 110 205 430 650 1220 1950 3450 7200 100 50 103 195 400 620 1150 18...

Page 14: ...input adjustment must not be less than 4 5 W C 1 12 Kpa for natural gas and 11 0 W C 2 74 Kpa for propane gas FIGURE 11 Do not subject the combination gas valve to inlet gas pressures of more than 14...

Page 15: ...Install in accordance with all local codes Use of the top inlet water connection requires installation of an inlet dip tube refer to figure 12 The tube is supplied in the heater Follow caution labels...

Page 16: ...OULD NOT EXCEED SAFE USE TEMPERATUREATFIXTURES SEEWATERTEMPERATURECONTROL WARNING ON PAGE 27 IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT ADD AN ANTI SCALD VALVE FOR...

Page 17: ...ED ON DURING THE RINSE OPERATION AND OPEN OFF WHEN DISHWASHER IS NOT OPERATING OR WHEN ON LONG STANDBY NOTE 2 INSTALL LINE TEMPERATURE CONTROL IN AN UNINSULATED TEE BEYOND THE DISHWASHING MACHINE TAKE...

Page 18: ...nstallation diagrams on the following pages are typical TWO TEMPERATURE TWO HEATERS ONE PRE HEATER ONE BOOSTER HEATER WITH OR WITHOUT BUILDING RECIRCULATION The discharge opening of the temperature an...

Page 19: ...TE 3 ADJUST PLUG COCK SO THE SANITIZING LOOP FLOW RATE DOES NOT CAUSE UNNECESSARY TURBULENCE IN THE TANK PIPE RELIEF VALVE TO OPEN DRAIN INSTALL IN ACCORDANCE WITH LOCAL CODES CIRCULATING RETURN LINE...

Page 20: ...GHER PREHEAT TEMPERATURESARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT ADDANANTI SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES INSERT A CAUTION IF BUILDING COLD WATER SUPPLY HAS A BACKFLOW PREVENTE...

Page 21: ...OOSTER OUTPUT ADD AN ANTI SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES PIPE RELIEF VALVE TO OPEN DRAIN WHEN USING A STATE T 140 200 350 OR 400 STORAGE TANK USE LOWER 3 4 OPENING FOR TANK TEMPERATURE...

Page 22: ...ANIFOLD KIT PART NO 78694 DIMENSIONS A INCHES CM MODEL LOW PROFILE VERTICAL HOOD A SBD MODELS 120 69 75 177cm 154 73 00 185cm 180 67 50 171cm 197 75 00 192cm 198 75 00 192cm 199 67 50 171cm 200 72 00...

Page 23: ...tallations contact State Water Heaters Technical Support Center at 1 800 527 1953 TABLE 5 MANIFOLD GAS PRESSURE IN INCHES OF WATER COLUMN ALL MODELS TYPE OF GAS NATURAL PROPANE 3 5 10 0 Gas pressure s...

Page 24: ...PURGE DISCHARGE MUST NOT ENTER CONFINEDAREASORSPACESWHEREIGNITIONCANOCCUR THE AREA MUST BE WELL VENTILATED AND ALL SOURCES OF IGNITION MUST BE INACTIVATED OR REMOVED WARNING THE GAS VALVE MUST HAVE B...

Page 25: ...25 FOR NATURAL GAS MODELS FOR YOUR SAFETY READ BEFORE OPERATING OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING...

Page 26: ...26 FOR PROPANE GAS MODELS FOR YOUR SAFETY READ BEFORE OPERATING OPERATING INSTRUCTIONS TO TURN OFF GAS TO THE APPLIANCE...

Page 27: ...the damper disc manually or motor damage will occur If the water heater does not operate with the Service Switch in either position Refer to the Troubleshooting Sections and Operational Checklist sec...

Page 28: ...REVENTIVE MAINTENANCE CHECK THE PILOT At least once a year check the pilot burner fig 14 and the main burner fig 15 for proper operation Refer to the following pilot and main burner sections PILOT BUR...

Page 29: ...a manometer to the gauge port and refer to Table 5 for correct manifold pressure 2 Use this formula to clock the meter Be sure that other gas consuming appliances are not operating during this interva...

Page 30: ...heater and replacement of the factory installed magnesium anodes with aluminum anodes may correct the condition Occasionally water softener companies recommend removal of heater anodes for odor reason...

Page 31: ...d screws securing tank cleanout plate and remove plate 4 Remove lime scale or sediment using care not to damage the glass lining 5 Inspect cleanout plate gasket if new gasket is required replace with...

Page 32: ...ed by the UN LIME it can be reused if not the UN LIME should be replaced TROUBLESHOOTING IGNITION MODULE SYSTEM Before calling your service agent the following checklist should be examined to eliminat...

Page 33: ...breaker 5 Disconnect switch off 6 Harness not plugged into appliance receptacle A FLUE DAMPER OPEN OR OPENING Unit is calling for heat and damper disc should be in vertical position VOLTAGE ACROSS 4...

Page 34: ...slower Call serviceman Check gas input If incorrect adjust gas pressure or replace main burner orifice Draft hood not installed or Call serviceman Install draft hood or baffles as one or more flue ba...

Page 35: ...35...

Page 36: ...36 500 Tennessee Waltz Parkway Ashland City TN 37015 Phone 800 365 0024 Fax 800 644 9306 www statewaterheaters com...

Reviews: