14
620-7925 Rev x1
Step 9.
Now screw in the coax adaptor to the coax ca-
ble coming out of the base neck.
Step 10.
Take the embedded display assembly to the
base unit. Hold the front display plastics at the
top with one hand while connecting the cables
and harnesses with the other.
Step 11.
Identify the four cables coming out of the neck
and mounting bracket:
1. Heart rate cable
2. Main I/O cable
3. Coax cable
4. DC power cable
1
2
3
4
Step 12.
Plug-in the heart rate cable from the neck into
the heart rate board connector on the FitCPU
board of the embedded display assembly.
Summary of Contents for E-STe