STAR Line Mode Command Specifications
3-48
ESC GS EM DC1 m n1 n2
[Name] External buzzer drive pulse condition settings
[Code]
ASCII ESC
GS
EM
DC1
m
n1
n2
Hex.
1B
1D
19
11
m
n1
n2
Decimal
27 29 25 17
m n1
n2
[Defined Area]
1
≤
m
≤
2
49
≤
m
≤
50
0
≤
n1
≤
255
0
≤
n2
≤
255
[Initial Value]
n1=0
n2=0
[Function]
Sets external buzzer derive pulse condition.
m specifies the buzzer drive terminal to perform the condition settings.
m
Buzzer Drive Terminal
1, 49
Buzzer Drive Terminal 1
2, 50
Buzzer Drive Terminal 2
n1 specifies the energizing time; n2 specifies the delay time.
• Energizing time:
=20msec x n1
• Delay time:
=20msec x n2
Drives for external buzzers set using this command is performed by <ESC> <GS> <EM> <DC2> m n1 n2.