6

Menu functions

Stabila LD 500

D

GB

SLO

F

I

E

P

NL

N

FIN

DK

TR

CZ

PL

S

HR

H

SK

LV

LT

KOR

RUS

CHN

EST

GR

RO

 key or the 

 key.

)

Parallax errors occur when the digital pointfinder is used on close 

targets, the laser dot may appear displaced in the crosshair. In this case you 
should rely on the actual laser dot for targeting the object.
See drawing {

F.2

}

1

Zoom step (1x, 2x, 4x)

2

Timer

3

Level (in °)

4

Crosshairs

5

Inclination angle

6

Distance tracking value

7

Image

Menu functions

Settings

Various device settings can be made in the menu. A vertical list shows each 
entry. In this menu the selection field (cursor) remains stationary and the 
list moves in a vertical direction. Starting from the centre of the list, the 
priority of list entries starts at the top and fans out clockwise. See drawing 
{

G

}.

The menu contains following items:

1

Timer

2

Laser continuous measurement mode

3

Display illumination

4

Digital Pointfinder image in black/white

5

Level in status field (in °)

6

Units of measurement (distance)

7

Long  range  mode

8

Units of measurement (angle)

9

Beep

10 Calibrate tilt sensor
11 Offset
12 Tripod
13 Reset

Navigation in the menu

The menu allows settings to be customized for a particular user or appli-
cation. 

General description

Press and 

hold

 the 

 key to enter the Setup menu.

By pressing the 

 or 

 keys, navigate through the main menu 

items in the menu.

Press the 

 key 

briefly

 to enter the submenu of the selected main 

menu item.

By pressing the 

 or 

 keys you can make the alterations in the 

submenu.

Press and 

hold

 the 

 key to accept the settings.

Pressing the 

 button 

for longer

 in the menu allows you to quit the 

settings function without saving.

Timer (

)

The time delay (default value) can be changed using the 

 or 

 

buttons. Pressing the button for longer increases the rate of change of the 
values. When you reach the desired time delay value, confirm it with the 

 button.

Summary of Contents for LD 500

Page 1: ...Operating instructions GB Laser Distancer LD 500 ...

Page 2: ...7 8 9 6 5 4 1 2 0 3 1 2 3 5 7 9 15 14 4 6 8 13 12 11 10 2 1 8 7 3 4 5 6 1 7 6 5 4 3 2 ...

Page 3: ...1 1 1 2 3 1 2 3 1 2 max ...

Page 4: ...will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or in appreciable material financial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Use of the instrument Permitted ...

Page 5: ...e person in charge of the instrument WARNING The person responsible for the instrument must ensure that the equipment is used in accordance with the instructions This person is also accountable for the deployment of personnel and for their training and for the safety of the equipment when in use The person in charge of the instrument has the following duties To understand the safety instructions o...

Page 6: ...most stringent requirements of the relevant standards and regulations Yet the possibility of it causing interference in other devices cannot be totally excluded CAUTION Never attempt to repair the product yourself In case of damage contact the local dealership Laser classification Integrated distancemeter The Stabila LD 500 produces a visible laser beam which emerges from the front of the instrume...

Page 7: ...anging the reference point multifunctional endpiece See figure B The instrument can be adapted for the following measuring situations For measurements from an edge fold out the positioning bracket until it first locks in place See figure C For measurements from a corner open the positioning bracket until it locks in place then push the positioning bracket lightly to the right to fold it out fully ...

Page 8: ...r this A horizontal line separates the measurement field and the result bar from one another A red triangle indi cates whether the selected measuring program has a detailed display avai lable 1 Program selection with measurement instructions 2 Program selection submenu 3 Level 4 Timer 5 Measurement field 6 Result bar 7 Detailed display 8 Status bar with Laser ON Reference plane Display Long range ...

Page 9: ...imer 2 Laser continuous measurement mode 3 Display illumination 4 Digital Pointfinder image in black white 5 Level in status field in 6 Units of measurement distance 7 Long range mode 8 Units of measurement angle 9 Beep 10 Calibrate tilt sensor 11 Offset 12 Tripod 13 Reset Navigation in the menu The menu allows settings to be customized for a particular user or appli cation General description Pre...

Page 10: ...2 Rotate the device horizontally through 180 3 Press the key and confirm that the device was rotated through 180 4 Press the key and take the second measurement The device confirms the measurement with The tilt sensor is calibrated Measuring with the tripod The reference point may be adjusted to the tripod mount if the user requires a measurement from the actual mounting grommit versus the front o...

Page 11: ...s the offset value is set Beep You can switch the beep on or off Long range Mode Unfavourable conditions strong sunlight or a very weak reflective target surface may reduce the range of the device in spite of this the long range mode allows you to take measurements over longer distances The use of a tripod and measurement initiation by pressing the key are recom mended when measurements over 30m a...

Page 12: ... It can also be used as determine spacings See figure I It is commonly used to measure room diagonals maximum values or hori zontal distances minimum values Press and hold down this button until you hear a beep Then slowly sweep the laser back and forth and up and down over the desired target point e g into the corner of a room Press to stop continuous measurement The values for maximum and minimu...

Page 13: ...m your entry with The value entered is divided by the measurement value Area Press once The symbol appears in the display Press this button to take the first length measurement e g length Press it again to take the second length measurement e g width The result is shown in the summary row Press and hold the key to display the perimeter Volume Press this button twice The symbol appears in the displ...

Page 14: ...de i 156 which means that the device has been tilted too much The units of inclination are set in the menu Press this button once to activate the tilt sensor The symbol appears in the display The tilt is continuously shown as or depending on the setting Press to measure the inclination and the distance See figure L Direct horizontal distance Press this button twice and the following symbol appears...

Page 15: ...ly folded out and the instrument placed on a wall or the Stabila LD 500 is mounted on a tripod The minimum maximum function can be used see explanation in Measuring Minimum maximum measurement The minimum value must be used for measurements at right angles to the target the maximum distance for all other measurements Indirect measurement determining a distance using 2 auxilliary measurements See f...

Page 16: ...get point Press this button to end continuous measurement The result is displayed in the summary line the partial results in the secondary lines Press and keep pressed the key to display additional information about the measurement of the partial lengths and Triangular area The area of a triangle can be calculated by the measurement of three sides See drawing N Press the key four times the triangl...

Page 17: ...lowing errors can be corrected Cause Remedy 156 Transverse tilt greater than 10 Hold the instrument without any transverse tilt 160 Main tilt direction angle too high 45 Measure angle up to max 45 162 The calibration has not been accomplished on a leveled surface and the calibration value is respecitvely within an ineli gible area Calibrate the device on an abso lute horizontal leveled surface 204...

Page 18: ...9 Area volume calculation of room data 9 Addition subtraction 9 Indirect measurement using Pythagoras 9 Trapezium measurement 9 Tilt measurements Tilt sensor Accuracy 2 σ standard deviation to laser beam to the housing 0 3 0 3 Indirect measurement using tilt sensor direct horizontal distance 9 Angle measurement using tilt sensor 45 9 General Laser class II Laser type 635 nm 1 mW Ø laser point at d...

Page 19: ...rrors can occur when measuring toward colourless liquids e g water or dust free glass Styrofoam or similar semi permeable surfaces Aiming at high gloss surfaces may deflect the laser beam and lead to measu rement errors Against non reflective and dark surfaces the measuring time may increase Care Do not immerse the instrument in water Wipe off dirt with a damp soft cloth Do not use aggressive clea...

Page 20: ...STABILA Messgeräte Gustav Ullrich GmbH P O Box 13 40 D 76851 Annweiler Landauer Str 45 D 76855 Annweiler Tel 00 49 0 63 46 309 0 Fax 00 49 0 63 46 309 480 e mail info stabila de www stabila de ...