13
Stabila LD 500
Functions
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Press and hold down this button to trigger continuous measurement
, sweep the laser up and down over the ideal target point.
Press to stop continuous measurement (2). The value is adopted. Aim
at the lower point and
press this button to trigger the measurement (3)
. The result is
displayed in the summary line, the partial results in the secondary lines.
Press and
hold
the
key to display additional information about for
example the partial distances
,
and the minimum distance
.
Indirect measurement - determining a partial value using
3 measurements
See figure {
R
}
e.g. determining the height between point 1 and point 2 using three target
points.
Press this button
three times
; the display shows the following
symbol
. The laser is switched on.
Aim at the upper point (1).
Press this button and trigger the measurement
. After the first
measurement the value is adopted.
Triggers the measurement
. After the second measurement the
value is adopted.
Press and hold down this button to trigger continuous measurement
. Sweep the laser up and down over the ideal target point.
Press this button to end continuous measurement. The result is
displayed in the summary line, the partial results in the secondary lines.
Press and
keep pressed
the
key to display additional information
about the measurement of the partial lengths
and
.
Triangular area
The area of a triangle can be calculated by the measurement of three sides.
See drawing {
N
}.
Press the
key
four times
- the triangle symbol
appears in the
display.
Press the
key and measure the first side of the triangle
.
Press the
key and measure the second side of the triangle
.
Press the
key and measure the third side of the triangle
.
The result
is shown in the summary row.
Press and
hold
the
key to display additional information about the
measurement, such as the angle
included by the first two measure-
ments and the perimeter
of the triangle.
Storage of constants / historical storage
Storage of a constant
You can store and recall a frequently used value e.g. height of a room.
Measure the desired distance, press and hold the
button until the
device beeps to confirm storage.
Recalling the constant
Press
twice
to call up the constant and then press the
button
to enter it into your calculation.
Historical storage
Press this button
once
and the previous 20 results (measurements
or calculated results) are shown in reverse order.
The
and
buttons can be used for navigation.