25
LEVEL GAUGE CLEANING
FILTER
1. With a suitable pliers release the clamp 1
fixing transparent tube of the level gauge.
2. Take off and remove the transparent tube 2 .
3. Remove the red plastic ball 3 .
4. Clean the transparent tube both inside and
out with clean water.
1
2
Gather the rinsing water in a proper
container provided to be waste according
to the rules or used again, putting
it in the tank, for a next treatment if
suitable with the product to be used.
Waste the transparent tube according
to the same method as per the pesticides
container.
5. If the cleaning is not satisfactory, replace the
transparent tube 2 .
6. Put the red plastic ball 3 into the transparent
tube 2 .
7. Install the transparent tube 2 making slip it
on the rubber fittings.
8. Place the clamps 1 fixing the transparent
tube 2 of the level gauge and close them
with a suitable pliers.
3
The suction filter is fitted with a shut-off valve which
closes automatically when the valve cap is screwed
off. This allows the filter cover to be unscrewed and
the element to be removed for cleaning while there
is fluid in the tank. Gloves should be worn when
handling the filter.
When the sprayer is operating the valve must be
fully screwed in to open the shut-off valve and allow
fluid to pass through the filter. Directional arrows are
moulded into the valve cap to show the opening and
closing operation.
ST101-GEO-i 400 / 600 LITER