23
A. FAULT
By utilising the filler piping the pump doesn’t operate (suction).
B. FAULT
Leakage and dripping from the pump.
It is necessary to disengage the drive outlet (PTO) and wait for it to stop rotating before
repeating the filling operation.
1. CAUSE
: The quantity of water poured into the tank is insufficient to trigger the pump.
REMEDY
:
Add water to the tank until the pump starts its cycle.
2. CAUSE
: The filler piping sucks in air.
REMEDY
:
Completely submerge the suction filter of the filler piping.
3. CAUSE
: Lack of seal of the pipes.
REMEDY
:
Check the tightening of ring nuts, fittings and clamps. Check the efficiency of
sealers and that piping elements are not cracked or broken. Replace parts
that are possibly found to be defective.
C. FAULT
Variations in the pressure.
D. FAULT
Vibrations of fan unit.
1. CAUSE
: Lack of seal of the pipes and/or the valves.
REMEDY
:
Check the clamping of the ring nuts, the connections and the clamps.
Verify the efficiency of the gaskets and the integrity of the pipes.
Replace the possibly defective parts.
2. CAUSE
: Residue of product at the entrance of the gauge
REMEDY
:
Clean.
3. CAUSE
: Lack of seal of the O-Ring gasket of the pump suction connection (cone).
REMEDY
:
Check the correct assembling and the efficiency of the O-Ring gasket, if
necessary replace the gasket.
1. CAUSE
: The tractor and of the atomizer PTOs are not lined up or their position determines
the overcoming of the maximum work angle of the drive cardan shaft.
REMEDY
:
Raise or lower the sprayer in order to realign PTO so that cardan shaft functions
correctly.
1. CAUSE
: Non-sealing of the fittings and clamps connecting the piping to the pump.
REMEDY
:
Check for proper tightening of ring nuts and clamps.
2. CAUSE
: Mechanical sealing defective.
REMEDY
:
Address to RB Spraytech Sdn. Bhd. point of “Sale and Service”.
FAULT FINDINGS
ST101-GEO-i 400 / 600 LITER
- Tractor Mounted