TROUBLE SHOOTING SPRAY PATTERNS:

A. A ROUGH OR STIPPLE FINISH

is due to low or restricted

flow of air pressure or heavy materials being applied with
the spray gun too close to surface.

B. A WET OR SAGGING FINISH

is due to low air pressure or

restricted  flow  of  air,  material  being  too  thin  or  applied  too
close to the surface.

C. A  SPUTTERING  SPRAY

is  caused  by  air  leaking  into  fluid

line or can be caused by a loose fluid tip, a broken or split tip,
lumpy material, a clogged vent hole in cover of material cup,
air  leak  at  fluid  pipe  attached  to  inside  of  tank  cover,  or  a
clogged paint strainer.

TO  CORRECT:

Tighten  tip  securely  or  replace.  Strain

material and clean strainer. Sputtering might also be caused
by worn packing washers, or worn or scored needle.

D. AN  ARCHED  FAN  SPRAY  PATTERN

is  caused  by  dried

material accumulated in one fan port of the aircap, distorting
the pattern.

Printed in the U.S.A.

Paasche Airbrush Company

4311 North Normandy Avenue

Chicago, IL 60634-1395

Phone:

773-867-9191 

• Fax:

773-867-9198

Website:  paascheairbrush.com

E-Mail:  [email protected]

K R G   &   K R S

Manual Spray Guns

OPERATING INSTRUCTIONS AND REPLACEMENT PARTS

TO CORRECT:

Dissolve material inside fan port with

suitable water/solvent applied with a small brush.

Never use wire or sharp instruments to clean fan ports
as  permanent  damage  to  the  air  ports  will  result  in
altering uniformity of the fan spray pattern.

E. UNBALANCED FAN SPRAY PATTERN

, heavy on one side,

may be caused by material collecting around outside of the
fluid tip and aircap, or by a loose aircap.

TO CORRECT:

Remove aircap and clean fluid tip and aircap

with water/solvent, dry with air pressure. Always be sure fan
aircap and aircap body is tightened securely.

F. A HEAVY CENTER

in a fan pattern is caused by insufficient

air pressure at the fan port. Rough or shady edges are also
caused by low air pressure.

TO CORRECT:

Increase air line pressure.

G. A SPLIT FAN SPRAY PATTERN,

heavy on each end and

light in the center, is caused by excessive air pressure.

TO CORRECT:

Reduce air pressure.

KRG MANUAL SPRAY GUNS
GRAVITY FEED HVLP

1.4  mm  Fluid  Nozzle  and  Needle.  20.29  oz.
nondrip plastic cup. Adjustable Fluid, Air and Fan
controls. 10.5 CFM @ 50 P.S.I.

Optional sizes available:
1.00 mm, 2.00 mm, 2.4 mm

Shipping Weight:  4 lbs. (1.8 kg)

KRS MANUAL SPRAY GUNS
SIPHON FEED HVLP

1.4  mm  Fluid  Nozzle  and  Needle.  One  Quart
Siphon with Clamp Cover. Adjustable Fluid, Air and
Fan controls. 11.5 CFM @ 50 P.S.I.

Optional sizes available:
1.00 mm, 2.00 mm, 2.4 mm

Shipping Weight: 4 lbs. (1.8 kg)

Features:

High quality finish. Nozzle and Needle components are made of durable Stainless Steel.

The  paint  flow  regulator  and  fan  regulator  allow  adjustment  of  quality  fan  spray.  Ergonomically
designed for your spraying comfort.