12.
Are there Cycle Time adjustments on the Control Board for different types of fuel?
Answer: There are 4 individual programs on the control board, each with a
different Cycle time.
The Control board has been factory set at the 7.5-second Cycle Time.
When reprogramming the control board, you will see all of the LED lights
flash, as shown in the figure to the right. The LED lights flash in the
following manner:
Program 1
- 7.5 second cycle time.
The LED’s flash
once
. This program
is for use with PFI Premium Pellets in the Eclipse-P.
Program 2
-
8.5 second cycle time.
The LED’s flash
twice
. This program
is for use with PFI Premium Pellets in the Eclipse-P.
Program 3
-
9.5 second cycle time.
The LED’s flash
three times
. This
program is for use with Cherry Pits, Corn, Wheat, Rye, and Distillers Grain
in the Eclipse-MF.
Program 4
-
10.5 second cycle time.
The LED’s flash
four times
. This
program is for use with Cherry Pits, Corn, Wheat, Rye, and Distillers Grain
in the Eclipse-MF.
13.
How do I change to a different Program on the control board?
First the Stove must be turned off and cooled down.
Step 1 - The Thermostat switch must be in the
Manual
position.
Step 2 – Press and hold the
Auger Feed
Button.
Step 3 – Press and hold both of the
Draft Trim
High and Low Buttons.
Release all 3 buttons at the same time.
Step 4 – Observe the LED light flashing as described in point 12 above.
Changing the Cycle Time will change the BTU Input of the Stove. The
longer the Cycle time the lower the BTU rating.
Figure 54
Figure 53