5.
Exhaust System.
See Figure 24, 25 and 26 for information on cleaning fly ash that
collects in the vent system. Periodic cleaning of the exhaust system is required. Under certain
conditions chimneys may plug up rapidly. Dirty poor quality Fuel, and poor installations require
more frequent chimney cleanings. The products of combustion will also contain small particles
of fly ash. The fly ash will collect in the exhaust vent and restrict the flow of the flue gases.
Judge the frequency of cleaning by checking the amount of ash that accumulates in the built in
Cleanout Tee in the exhaust system. Ask the dealer for suggested frequency of cleaning,
equipment needed and procedures for cleaning. Check the Vent Cap at least once every two
months during the heating season to see if it has become plugged.
See Page 24 “Preventing
Chimney Fires”
.
6.
Gaskets.
Periodically inspect the condition of the rope gasket around the door, window
and ash door. Replace as needed.
Yearly Maintenance
Many dealers offer a Service Contract that will cover Yearly Maintenance. Contact your St.
Croix Dealer for assistance in maintaining your Ashby-P in top condition. Yearly maintenance is
designed to assure safe operation, prolong the life of the Ashby and help preserve its aesthetic
appeal.
1.
Spring Shutdown.
After the last burn in the spring let the unit cool down. Remove all
fuel from the hopper and the auger. Thoroughly clean the burn pot, burn pot box, ash pan and ash
traps behind the ash pan. (To locate the ash traps see figure 24)
2.
The exhaust system should be thoroughly cleaned at least annually. Call your dealer for
this service. (See figure 27 on the following page)
3.
The motor/fan area behind the firebox and under the hopper should be vacuumed
annually. (See figure 27 on the following page)
NOTE: UNPLUG THE INSERT
. Remove the Surround panels of the Ashby-P and pull the
unit from the fireplace. Carefully clean or vacuum any dust, cobwebs and household dust.
Carefully vacuum around the fan motors. If electrical wires become disconnected call your
dealer for service.
4.
The exhaust fan should be removed and cleaned with compressed air annually. Call dealer
for this service. Annual oiling of the motors is not needed. (See figure 27 on the following page)
5.
The Convection fans should be removed and cleaned with compressed air annually. (See
figure 27 on the following page)
6.
Replace the Door Gaskets if needed.
7.
Replace the Ash Pan Door gaskets if needed.