Ashby-P Insert
Page 28
3. The On/Off button not only turns the Stove On and Off, it also resets the board if one of the
sensors has detected a problem and the board is flashing a Diagnostic code.
4. The Draft Trim button allows for adjusting the Exhaust (Combustion) fan voltages up or
down providing for fine-tuning of the combustion air. The LED light bar indicates the level of
adjustment and the factory setting is the center LED light. This allows for 2 adjustments up and 2
adjustments down. (See point 9 on page 47)
To adjust the Combustion Fan voltages:
Hold the Auger Feed button down and press the Draft Trim High/Low button and this will
change the fan voltage approximately 2.5 volts up or down from the factory setting. Watch
the LED lights to see the setting is on (it will flash the new setting). This new setting will
stay in memory from this point on.
5. The Thermostat Slide switch allows the Insert to be run in 3 different Modes:
a.
Manual Mode
. The Control Board controls all functions of the Ashby-P.
b.
T-Stat Mode
.
The Stove is Fully-Automatic in the T-Stat Mode.
(T-Stat requires the stove
be turned on at the control board the first time).
The unit is hooked to a Thermostat and
when calling for heat the unit will advance to the Heat level set at the Control board.
Once the Heat demand has been met, the Stove will immediately shut down. Use this
setting when heating a small area or when Temperatures are Moderate.
c.
SmartStat Mode
. The unit is hooked to a Thermostat and when calling for heat the Insert
will advance to the Heat level set at the Control board. Once the Heat demand has been
met the Insert will drop to the #1 Heat Level setting
and pilot for one hour
. If the
Thermostat does not call for heat during that hour the unit shuts off and
re-lights itself
the next time the Thermostat calls for heat
. This setting is best used during early Fall or
late Spring, when constant heat is not needed.
6.
Cleaning Cycle.
The Ashby-P only uses Programs 3 & 4. This allows the Ashby-P to operate
in an Automatic mode using the Igniter. These 2 programs have a Cleaning Cycle built into them
that allows
the unit to drop to the #1 level for 5 minutes on timed intervals. During the cleaning
cycle the Combustion Fan will run at line voltage to blow excess ash from the burn pot.
The
ON/OFF light blinks (slowly)and the control board is locked out during this cycle
.
Pre-Lighting Instructions
The Control Board has 4 separate programs. Two of the programs are for the Ashby-MF
(Programs 1 & 2) and two of the programs are for the Ashby-P (Programs 3 & 4). Before
lighting the Insert for the first time, ask your dealer about how to change the program or read the
instructions on the following page. The unit is set to the default program, which is program 3.
There is no feature to check to see which program is running. You must change it to see what
program was running and then cycle back through the programs to revert to program 3.