SSS Siedle DCIP 740-0 Manual Download Page 6

6

3  Terms

Camera assignment

A Siedle Multi door station can be 
assigned up to 49 different PC users. 
This operating mode is only possible 
with DCIP 740-... 

Client

PC user connected to a network.

Full duplex

Both users (PC client and door 
station) have an unrestricted 
speech connection. Open duplex 
communication, i.e. as opposed to 
the simplex speech mode.

Gateway

Gateways link two different 
networks and create connections 
across network boundaries. During 
this process, both the physical 
transmission modes and also 
protocols and addresses are adjusted 
accordingly.

Half duplex

Two speaking users have one speech 
connection which they can use 
alternately, also known as push to 
talk.

HTTP

The Hypertext Transfer Protocol is a 
protocol used for the transmission 
of data via a network. It is used 
mainly to load websites and other 
data from the Internet into a web 
browser.

Hub

The term hub when used in relation 
to network technology describes a 
device which links network nodes in 
a star formation. Normally, the term 
hub is used to denote a multiport 
repeater. It is used in order to link 
network nodes or other hubs, for 
example by means of an Ethernet.

IP address
Internet Protocol address

An IP address is a number which 
permits PCs and other devices in 
an IP network to be addressed. In 
technical terms, the number is a  
32- or 128-bit binary number.

registrations. In total, this adds up 
to 25*2=50, which is the maximum 
possible assignment per IPVS.

In the following is a list with five 
combinations. Each example compri-
ses a group with a different number 
of users and individual clients. 

Clients 
in group

Individual 
Clients

Calculation

5

40

5*2+40=50

10

30

10*2+30=50

15

20

15*2+20=50

20

10

20*2+10=50

25

0

25*2+0=50

Example in case of several 
groups:

The following is a combination 
example comprising two groups 
and five individual clients, with each 
group and each individual client 
occupying one address. Consequent-
ly a total of seven addresses are used 
in the system.
Group 1: 20 PC users 
Group 2: 5 PC users 
Clients: 5 individual PC users 
• If the biggest group (group 1) is 
called, this group occupies 20*2=40 
registrations in the IPVS. Group 2 
and the individual PC users each 
occupy 5 registrations. In total, this 
adds up to 20*2+5+5=50, which is 
the maximum possible assignment 
per IPVS.

Monitor assignment mode:

• If no groups are created, a 
maximum of 4 single PC users can 
be integrated. If one of these PC 
users is called, it currently occupies 
2 registrations, the others occupy 
only one each. In total, this adds 
up to 1*2+3=5. In this operating 
mode, this represents the maximum 
number of users.
• If several groups are created, the 
biggest group is decisive for the 
calculation. The maximum group 
size is 25. If this group is called, 
each PC user currently occupies 2 
registrations. In total, this adds up 

to 25*2=50, which is the maximum 
possible assignment per IPVS.

In the following is a list with four 
combinations. Each example compri-
ses a group with a different number 
of users and individual clients. 

Clients 
in group

Individual 
Clients

Calculation

23

3

23*2+3=49

24

2

24*2+2=50

24

1

24*2+1=49

25

0

25*2+0=50

Example in case of several 
groups:

The following is a combination 
example comprising two groups and 
two individual clients, with each 
group and each individual client 
occupying one address. Consequent-
ly a total of four addresses are used 
in the system.
Group 1: 20 PC users 
Group 2: 8 PC users 
Clients: 2 individual PC users 
• If the biggest group (group 1) is 
called, this group occupies 20*2=40 
registrations in the IPVS. Group 2  
occupies 8 registrations and the 
two individual PC users each 
occupy one. In total, this adds up to 
20*2+8+2=50, which is the maxi-
mum possible assignment per IPVS.

For parallel calls to groups, note the 
section on multicasting, page 22.

Summary of Contents for DCIP 740-0

Page 1: ...Manual DoorCom IP DCIP 740 0...

Page 2: ...Software 11 Siedle Multi 12 5 Installation Wiring diagrams DCIP 740 0 Terminals DCIP 740 0 14 LED display SIVS 610 15 Block diagrams 16 Wiring diagram Siedle Multi 17 6 Commissioning DCIP 740 20 SIM...

Page 3: ...building installation with a contact opening of at least 3 mm Ensure that the connection point in the building installation is fused with max 16 A When planning the required distributor space for swit...

Page 4: ...4 call destinations i e Siedle Multi system addresses can be assigned to the interface SIM 740 These correspond to the functions of the 4 Multi telephones The call destination can be dialled from eve...

Page 5: ...levant product information and programming instructions of the manufacturer Mounting and installation The DCIP 740 can be connected at any optional point of the Siedle Multi system bus The devices are...

Page 6: ...ample comprising two groups and five individual clients with each group and each individual client occupying one address Consequent ly a total of seven addresses are used in the system Group 1 20 PC u...

Page 7: ...a protocol arriving at the router are analysed for information and forwarded or routed to the intended destination network RS232 Designation for a serial interface for instance the COM interface of a...

Page 8: ...tion 25 mA per call button module TM 612 Used as call buttons 1 4 directly at the SIVS 600 TME 645 0 Call button module extension with interface to the Vario bus for max 8 TME 645 Suitable for connect...

Page 9: ...abetical input module with keypad A I Input unit for alphanumerical selection of PC users For use in Siedle Multi systems only in conjunction with the TLC 640 02 COM 611 01 DIM 640 0 and SIVS 600 Oper...

Page 10: ...red for configuration of the system interface video server with software DCIP CO 600 version 1 1 or higher IPVS 600 0 System interface video server Processing and adjustment of audio and video transmi...

Page 11: ...iguration software PC program for set up and programming of the Siedle interface video server SIVS 610 Programming takes place via the USB programming interface PRI 602 USB configuration software vers...

Page 12: ...s able to simulate several Multi telephones depending on the operating mode Only one of these virtual telephones can ever be active at one time i e conduct a call Dimensions 107 x 89 x 60 mm VMS 641 0...

Page 13: ...loudspeaker for camera on With DoorCom IP the contact is permanently active Potential is switched via the UPS terminal VKA Actuation of camera distributor M is switched A1 A1 Potential free contact f...

Page 14: ...ghts up in green with an existing network connection g LED T flashes orange on data transmission via the network Terminals IPVS 600 0 h Video input 1Vss from the SIVS 610 i Audio Line In to the SIVS 6...

Page 15: ...ive possibly new software update or exchange ON Slow flashing Variobus address error error remedy possible on site ON Fast flashing The 15 V power supply terminal bv cv is overloaded Error remedy poss...

Page 16: ...s Supply voltage 24 V DC T not used DR via T TLC 640 02 Li not used USP Universal Serial Port SN1 RF signal path SN2 SIM 740 SIVS 610 n1 RF signal for n2 connected DCA 740 01 Block diagram SIM 740 0 S...

Page 17: ...17 Monitor assignment mode 5 Installation DCIP 740 Siedle multi Siedle Multi requires additional supply devices which are not listed in this wiring diagram...

Page 18: ...18 5 Installation DCIP 740 Siedle multi Camera assignment mode Siedle Multi requires additional supply devices which are not listed in this wiring diagram...

Page 19: ...small number of doors and a large number of PC users Monitor assignment mode Up to a maximum of 4 call destinations i e Siedle Multi system addresses can be assigned to the interface These correspond...

Page 20: ...alled on the PC users in the network Import of the generated file dcip Selection of addresses to be signalled on the affected PC user Step 1 Issue of the IP address and subnet mask in the IPVS 600 The...

Page 21: ...h to be able to reach the SIM 740 or the relevant PC users The master monitor address is already entered The DCIP Software Client is the PC on which a Siedle in house telephone is depicted by the soft...

Page 22: ...parately in each IPVS 600 Multicast address video 1 For each IPVS 600 enter a multicast address which you wish to operate in the multicast mode duplication of the data streams in the network With the...

Page 23: ...23...

Page 24: ...rements for the configuration software PC with Intel Pentium III from 1 GHz or comparable processor at least 256 MB RAM min 25 MB hard disk memory Serial COM interface RS232 or serial USB adapter CD R...

Page 25: ...the configuration to the SIM 740 with Send configuration Below entries are details of the SIM 740 and the SIVS 610 synchronized There is also the associated phone number given System initialization on...

Page 26: ...are Client The Software Client configuration can be opened by pressing the right hand mouse button on the virtual in house telephone In the first tab Configuration select add DCIP SC file and import t...

Page 27: ...ff If there is an active firewall the application file DCIP SC 600 0 exe must be defined as an exception or as a permanently authorized program application In order to establish a video link it may be...

Page 28: ...ction SW1 OFF 0 dB as delivered status ON 9 dB Level adjustment TLM 645 Setting the volume of the PC user from the door station in the direction of the PC user Establish the connection to the PC At th...

Page 29: ...be switched off If the number 61 is pressed the door release is actuated for 3 seconds For connection of more than one telephone a so called group call or collective call function must be set up in th...

Page 30: ...this to 32 MB this problem occurs primarily with laptops Set the hardware acceleration of the graphics card display to max Speech goes from the PC only in the direction of the door Enter the software...

Page 31: ...31...

Page 32: ...d using a digital multimeter Idle status min max Voltage at line rectifier NG 608 24 V DC 28 5 V DC Voltage b c at SIVS 610 15 V DC Voltage Da Db at SIVS 610 0 3 V DC Speech mode Voltage M at CMC 612...

Page 33: ...laims to damages Connection 17 As delivered status 29 Block diagram 13 Camera assignment 4 6 Client 6 26 Commissioning 20 Config 20 Cross over 20 DoorCom 10 Factory setting 29 Full duplex 6 HTTP 6 IP...

Page 34: ...2007 02 09 Printed in Germany Order no 0 1101 037156 EN S Siedle S hne Postfach 1155 D 78113 Furtwangen Bregstra e 1 D 78120 Furtwangen Tel 49 7723 63 0 Fax 49 7723 63 300 www siedle de info siedle de...

Reviews: