3
DoorCom IP 740-0
Siedle DoorCom IP links the Siedle
world of building communication
to the IP world. Door calls are
transformed via the DoorCom IP and
transmitted via the IP network
to certain PCs. If video cameras
are fitted at the door station, the
picture of the visitor is additionally
transmitted. The DoorCom IP
Software Client is used here as
a virtual in-house telephone for
communication to the door station.
The Software Client must be
installed on every PC in the network
which is intended to receive a door
call. Assignment of door calls to the
Software Clients takes place using
an IWA address (Interface Working
Address) which is entered in the
DoorCom IP with the aid of the
configuration software.
DCIP 740-0
The DoorCom IP 740-... serves as
an interface between a Siedle Multi
system and an IP network.
The DoorCom IP is able to display
the picture on the PC monitor in
conjunction with the Siedle Software
Client and at the same time hold the
door call via the PC. The door call
can optionally also be held over the
telephone system using a telephone,
while the picture is displayed by
the Software Client and all control
functions such as door release can
also be initiated by the software. For
this, a DCA 740-01 must additionally
be connected to the DoorCom IP.
Danger
Mounting, installation and
servicing work on electrical
devices may only be performed
by a suitably qualified electrician.
Failure to observe this regulation
could result in the risk of serious
damage to health or fatal injury
due to electric shocks.
•
When working at the device,
observe the instructions for mains
cut-off.
•
Observe the standard DIN EN
60065!
When establishing the electronic
connection, observe the
requirements of VDE 0805 / EN
60950.
•
An all-pole mains switch
must
be
provided in the building installation
with a contact opening
of at least 3 mm.
•
Ensure that the connection point
in the building installation is fused
with max. 16 A.
•
When planning, the required
distributor space for switch panel
mounted devices must be taken into
account.
•
External voltages >30 V AC/
DC must not be injected into the
in-house telephones.
Devices with 230 V connection
In accordance with DIN VDE 0100
Part 410, Section 411.1.3 ensure
that the DoorCom installation and
the mains voltage are securely
isolated. The sheathing of the
connection cable (safety extra-low
voltage) should only be stripped
back far enough to ensure that
reliable connection is possible.
For mains connection
!
and network settings such as
assignment of the IP address, the
responsible network administrator
must be consulted.
1 System description
DoorCom IP 740-0
2 Safety remarks
System requirements
Find out about the necessary safety
measures and system requirements
before starting installation and
commissioning of the DoorCom IP.
System requirements
for the configuration software
• PC with Intel Pentium III from
1 GHz or comparable processor
• at least 256 MB RAM
• min. 25 MB hard disk memory
• Serial COM interface RS232 or
USB interface
• CD-ROM drive for installation
• VGA graphic card with
at least 1024 x 768 pixel
• Operating system Windows 2000/
XP
• Admin rights for installation
Additional memory capacity is
required for:
• Acrobat Reader 7
• Microsoft Internet Explorer from
version 4
System requirements
for the Software Client
•
Operating system Microsoft
Windows 2000/XP
•
Pentium IV from 1.8 GHz or
compatible CPUs
•
min. 256 MB RAM
•
Graphic card with
at least 1024 x 768,
128 MB and 16 bit colour depth
MPEG 4 capability
•
100 Mbit Ethernet card
•
Sound card
•
Microsoft DirectX 9.0b or newer
•
Microsoft Internet Explorer
from version 4.0 for reading the help
Speech quality
The audio quality (speech
transmission) is highly dependent on
the quality of the audio components
built into the PC (headset, handset
and sound card).