steP g - Fix disPenser in PLACe
1. Prop the Dispenser 5 to 10mm above the
bench to create a gap between the sink
flange and the bench surface;
2. Apply silicone or a similar sealant to the
bench surface under the sink flange. Follow
sealant manufacturer guidelines to ensure the
bond is strong and will not leak;
3. Remove props and carefully lower the
Dispenser into place;
4. Clean off excess sealant and allow to cure.
steP h - CoMMissioning FreePour
1. Visually inspect all connections to ensure they
are sound and in the correct place;
2. Plug the Chiller into a power supply of 220-
240 Volt AC and switch on;
3. Plug the Control unit into a power supply of
220-240 Volt AC and switch on;
NOTE: So you do not need to use bladders to test
for leaks and correct operation, set the system up
as if you are about to run the cleaning routine. Do
not add chemical to the water. See page 19 for
instructions on setting up the cleaning routine.
4. Press and hold activation button for each tap
and watch the stream of water to see that it
eventually runs clear without bubbles.
NOTE: A persistent stream of bubbles in the water
being dispensed may indicate a leak is present
somewhere in the system. You may need to top up
the cleaning bottle a few times during this test.
steP i - Assess ChiLLer drAin PLug
Some Chillers have a floor drain and plug.
IMPORTANT:
If fluid cannot drain away or
be easily collected, the drain plug should be
permanently sealed in place with silicone so it
cannot be removed. This is especially important
where a Chiller has been installed on a plinth.
beFore First serViCe
Run the Cleaning Routine and inspect for normal
operation. See page 19 for instructions on how to
run the cleaning routine.
oPtionAL ProCedures
For the majority of applications the default
software settings will not need to be changed.
The two exceptions to this are:
1. Dose Time
This can be used, for example, to set a
recommended serve size or to discourage
excessive dispensing.
2. Flow Rate
This may be changed, for example, to slow
the rate of dispense into an unusual shaped
vessel to reduce the chance of overfilling.
ChAnging the dose tiMe
Use the interface on the Control Unit to change
the Dose Time:
1. Use
keys to navigate through MENU /
MAXIMUM DOSE ADJ
to enter into the
MAXIMUM DOSE ADJ menu;
2. Use the adjustment dial to change the Dose
Time (in seconds) for Tap A;
3. Use
key to navigate to Tap B;
4. Use the adjustment dial to change the Dose
Time (in seconds) for Tap B;
5. Use
key to navigate back to the FREEPOUR
screen.
Installation Overview & Procedure
l
15
14
l
Installation Overview & Procedure
ChAnging the FLow rAte
Flow Rate is in a hidden menu to help ensure it is
not changed by accident.
WARNING:
The hidden SETUP menu contains
many essential system settings. We do not
recommend changing any settings in the hidden
SETUP menu unless you are sure you understand
the purpose of the setting and likely consequence.
To access the hidden SETUP menu:
1. Switch Freepour to MANUAL using the ON-
MANUAL BACKUP switch on the Control Unit;
2. Press and hold the UP and DOWN navigation
keys and switch Freepour to the ON position;
3. Wait to see DEBUG MODE appear briefly on
the screen, then release the UP and DOWN
navigation keys.
To change the Flow Rate:
1. Use
keys to navigate through MENU /
SETUP / OTHER SETTINGS. Press
to enter
into the OTHER SETTINGS menu;
2. Use
key to navigate to pump A speed
adjustment screen;
3. Use the adjustment dial to change the pump
speed (as a % between 0 and 100) for Tap A;
4. Use
key to navigate to pump B speed
adjustment screen;
5. Use the adjustment dial to change the pump
speed (as a % between 0 and 100) for Tap B;
6. Use
key to navigate back to the FREEPOUR
screen.
ChAnging the ProduCt tyPe bAdges
The badge holder can be removed from the taps
by firmly pulling the badge holder upward using
the technique shown below.
WARNING:
Support the tap when removing the
badge holder otherwise the tap may be damaged.
The badge holder can be fixed to the taps by
inserting the badge holder into the slot in the tap
and firmly pushing the badge holder down using
the technique shown below.
WARNING:
Support the tap when replacing the
badge holder otherwise the tap may be damaged.