SSM Freepour User Manual And Installation Manual Download Page 12

4. Freepour Chiller

Freepour Chiller  

l

  

21

20

  

l

  

FreePour ChiLLer

Changing settings that relate to the operation of 

the Chiller is performed through the electronic 

controller.

The electronic controller is visible through a cut 

out in the front panel.  It controls and displays 

the cabinet interior temperature and signals 

temperature alarms. It uses temperature probes 

around different areas of the refrigeration system 

to collect data and to run the cabinet accordingly.

The electronic controller is pre-programmed 

and requires no initial setup or additional 

programming. We do not recommend that 

the settings be changed unless it is absolutely 

necessary.

CAreL eAsy eLeCtroniC ControLLer

Because the electronic controller plays such an 

important role, it’s helpful to know the parts of 

the faceplate you may use.

1.  Compressor Indicator

2.  Display

3.  Stand-by (up) button

4.  Mute (set) button

5.  Manual defrost button

NOTE:  See the table on page 21 for the function of 

each item above.

stAnd-by Mode

Press and hold the stand-by button for three 

seconds to turn stand-by mode on or off. When 

stand-by mode is on, the controller display will 

alternate between the cabinet temperature and 

Of,

 and the compressor, fans and alarms are 

disabled.

The interior light is still activated by the door 

switch and will come on when a door is opened.

teMPerAture setPoint

The temperature setpoint is factory set and can be 

adjusted if necessary.

We do not recommend that the setpoint be 

changed unless it is absolutely necessary, and 

then only by small increments at a time.

To view and adjust the temperature setpoint:

1.  Press and hold the 

set

 button until the 

controller display shows 

SEt

 followed by a 

temperature value. The temperature value is 

the current setpoint.

NOTE:  If 

PS

 appears on the display, the set button 

has been held for to long. Release it, then press the 

set

 button twice to restart the procedure.

2.  Press the 

up

 and 

down

 buttons to adjust the 

value to the required setpoint.

3.  Press the 

set

 button again to store the new 

setpoint value.

 

Carel Easy - Icons and Functions

Item

Icon

Function

1

Compressor indicator

 

ON when the compressor and condenser fan starts.  

Flashes when activation of the compressor is temporarily delayed.

2

display

 

Shows the cabinet temperature.  

Flashes when the door is open.

3

stand-by (up) button

  

Turns stand-by mode on and off.  

To scroll settings up (in program mode).

Note: This is not an isolation switch.

4

Mute (set) button

Mutes the audible alarm (buzzer) and deactivates the alarm relay, and used in 

program mode.

5

Manual defrost button

Press for more than 5 seconds to initiate manual defrost.  

To scroll settings down (in program mode).

Carel Easy - Messages and Alarms

Code

Alarm

Action

Defrost cycle in 

progress message

Cabinet is running correctly.  

Message will stop displaying once the defrost cycle is complete.

Temperature sensor 

fault alarm

Reset alarm by unplugging the cabinet from the power supply  

for one minute, then reconnect.

If alarm persists, arrange a service call.

Product low 

temperature alarm

Product high 

temperature alarm

Parameter error alarm

Defrost error alarm

1

2

3

5

4

Summary of Contents for Freepour

Page 1: ...User Manual and Installation Guide This guide applies to Freepour 1 0 dispenser range Item codes JUG2 0 CM 13 JUG2 0 CM 23 JUG2 0 CM 14 JUG2 0 CM 14 www sixsimplemachines com au D00142 A05...

Page 2: ...HACCP based Food Safety Programme This HACCP endorsement is conditional to the following requirements 1 Freepour must not be operated for more than one day without performing a full clean sanitise usi...

Page 3: ...During Service 18 Dispensing product 18 Reloading During Service 18 Reloading a Connect 4 Chiller 18 Reloading a Connect 8 Chiller 18 Blanking 18 Operating Freepour After Service 19 Daily Cleaning Rou...

Page 4: ...ned by a water jet This unit can be used up to an altitude of 2000 meters above sea level The unit is designed to operate in ambient temperatures between 16 C to 38 C If the unit is to be installed wh...

Page 5: ...ternal configuration you may be able to connect all bladders loaded or as few as one bladder at time IMPORTANT Only approved varieties of milk and fruit juice may be dispensed Approved varieties of mi...

Page 6: ...lows for a variety of installation configurations to suit your dispense station layout When deciding where each of the three units will be located consider how the machine will be used in service relo...

Page 7: ...ed to site on standard height castors Short roller style castors can be supplied by request and fitted on site Operation Automatic Start Up Connect the cabinet to the mains power supply and check oper...

Page 8: ...firmly up to the fitting at the base of the tap Observe the stickers on the protective sleeves showing the tap and Chiller ends of the sleeve 2 Feed insulation over the fluid product lines Fasten in...

Page 9: ...hanged for example to slow the rate of dispense into an unusual shaped vessel to reduce the chance of overfilling Changing the Dose Time Use the interface on the Control Unit to change the Dose Time 1...

Page 10: ...g features are not active In the event that the electronics are malfunctioning Freepour can still dispense milk as long as the internal power supply and pumps are still active No dosing and programmin...

Page 11: ...e Control Unit MENU CLEANING ROUTINE 2 Remove trays with empty bladders Discard empty bladders and wash the trays 3 Remove trays with partially full bladders To prevent bladders leaking from the cap f...

Page 12: ...setpoint be changed unless it is absolutely necessary and then only by small increments at a time To view and adjust the temperature setpoint 1 Press and hold the set button until the controller displ...

Page 13: ...or more frequently if required See page 23 for instructions on how to clean the condenser coil IMPORTANT Unplug the cabinet from the power supply before cleaning the condenser coil Over time dust may...

Page 14: ...shown on screen If the NO CURRENT error is displayed on screen The pump cable may have become disconnected The circuit breaker s may have tripped A pump may be jammed or The pump s may have failed Rec...