3.
DESCRIPTION OF FRONT PANEL
The Front Panel
BEEPER
The beeper sounds when the buffer is 95% full and also indicates status changes.
LED INDICATORS
LED INDICATORS
DOWN LOAD
Indicates that the logging server has responded to buffer.
ON when logging server has responded to buffer or a TCP session is
connected to Socket 0 (either MMI or NetLog), flicks off when data sent.
Off when Serial connected, flashes on when data sent.
HEARTBEAT
Flashing indicates that the unit is operational.
Double flash indicates some data in the buffer (64 or more characters)
Triple flash indicates more data in buffer (2048 or more characters)
50% full
This LED flashes when buffer is 50% full.
80% full
This LED flashes when buffer is 80% full.
IP OK
Indicates that the IP address is OK or that DHCP was successful if
enabled.
TIME SVR
Indicates the time server returned a valid time.
PABX RX
Indicates when data is received from PABX, either via the serial or via the
LAN interface, thereby providing visual confirmation that the buffer is
receiving data from the PABX.
PABX CON
Indicates when IP connection is active to the PABX.
PWR
This LED indicates that power is being received from the external 12 volt
power supply.
GSM PWR
This LED indicates that power is being received from the buffer.
GSM STATUS
This LED flashes with a 50% duty cycle when searching for the GSM
network.
It flashes with a 10% duty cycle when logged onto the GSM network.
Permanently on when contact has been established with the server.