COMMAND TABLE
Command
Description
PRT <0, 30 to 255>
Set the PAD reset timer. This timer causes the LAN module to be
restarted when it expires. It can be disabled by setting it to zero.
Attempts to set it below 30 minute will result in it being set to 30
minutes. The maximum value is 255 minutes.
The timer is restarted when the SS-
77 receives an „S‟ or „SEND‟
command.
SEND <nn>
Sends the number of records specified by <nn> on the MMI port that
was used to enter the command. The records will be preceded by a
line with the text:
DataBlock
Followed by the lesser of the number of requested records or that
actual number in the buffer. This is followed by:
TotalRecords x
Where „x‟ is the actual number of records sent.
If the buffer is empty it sends the message “NO DATA<enter>”.