![SS Telecoms SS-76 NG User Manual Download Page 16](http://html.mh-extra.com/html/ss-telecoms/ss-76-ng/ss-76-ng_user-manual_1354337016.webp)
SS-76 NG USER MANUAL
DOC. NO: SS-76 NG (REVISION 05)
Page 16 of 19
8.4
SYSLOG SETUP
When the SYSLOG logging option has been selected then no other options need to
be selected. The logging (UDP listening port) will automatically be set to 514 and
the socket will be set to UDP. Any packets received will be store with an appended
Carriage Return character. Optionally the date will be stored too using the normal
date storage settings.
8.5
PHILIPS SOPHO IPS 2000
PHILIPS SOPHO IPS 2000 IP COMMANDS
The IPS 2000 is logged using an IP connection. The PABX acts as the server and the buffer
connects to its client.
Command
Description
SII <IP address>
This sets the IP address of the PABX. The port number is fixed at
60010.
8.6
PHILIPS SOPHO CPU 4000
PHILIPS SOPHO CPU 4000 IP COMMANDS
The CPU 4000 is logged using an IP connection. The PABX acts as the server and the buffer
connects to its client.
Command
Description
SII <IP address>
This sets the IP address of the PABX. The port number is fixed at
2599. The command is the same as for the Sopho 2000 IPS.
8.7
FTP CLIENT
FTP CLIENT IP COMMANDS
The SS-76NG logs into the PABX using IP address. Most servers will set the Working Directory to
the correct directory for the user.
Command
Description
FTI <IP address>
Sets the IP address of the PABX. This needs to e be in dotted notation,
e.g. 192.168.0.234
FTU <username>
Sets the FTP Username. Maximum 12 characters.
FTP <password>
Sets the FTP password for Username. Maximum 12 characters.
FTF <filepath>
This selects the directory from which to extract the files. Maximum 29
characters.