Installation
Waukesha Cherry-Burrell
Page 14
95-03057
October 2005
The steam solenoid is opened, which lets pressure controlled steam from the boiler into the jacket. A temperature sensor
monitors the temperature of the product and regulates the steam flow to achieve the required temperature. Heating of the
product takes place when the steam condenses into water from the transfer of heat through the jacket.
Table 1: Call Outs For Figure 4
Figure 4 - Suggested Media Piping, Steam
1. Steam IN
7. I/P
2. Strainer
8. Temperature Control
3. By-Pass Line
9. Product OUT
4. Steam Pressure Regulator
10. Product IN
5. Steam Solenoid
11. Drain Valve
6. Temperature Regulator
12. Condensate Trap