background image

General Description

This airless sprayer is a precision power tool used for spraying
many types of materials.  Read and follow this instruction
manual carefully for proper operating instructions,
maintenance, and safety information.

Operation

This equipment produces a fluid stream at extremely high

pressure.  Read and understand the warnings in the

Safety Precautions section at the front of this manual

before operating this equipment.

Setup

Perform the following procedure before plugging in the power
cord of an electric unit.

1. Ensure that the siphon tube/suction set and the return

hose are attached and secure.

2. Using a wrench, attach a minimum of 50’ of 1/4” nylon

airless spray hose to the outlet fitting on the sprayer.
Tighten securely.

3. Attach an airless spray gun to the spray hose.  Using two

wrenches (one on the gun and one on the hose), tighten
securely.

Make sure all airless hoses and spray guns are electrically

grounded and rated at or above the maximum operating

pressure range of the airless sprayer. 

4. Make sure the pressure control knob is in the “0” (OFF)

position.

5. Fill the oil cup with approximately one tablespoon of

separating oil (P/N 0279920).

Never operate unit for more than ten seconds without

fluid.  Operating this unit without fluid will cause

unnecessary wear to the packings.

6. Make sure the electrical service is 120V, 15 amp

minimum.

7. Plug the power cord into a properly grounded outlet at

least 25’ from the spray area.

CAUTION

WARNING

NOTE: Do not attach the tip to the spray gun yet.

Remove the tip if it is already attached.

WARNING

Siphon 

Tube

Pressure 

Control

Knob

Oil Cup

Fuse

Fluid 

Section

Filter

Motor

PRIME/ 

SPRAY 

Valve

Outlet 

Fitting

Return 

Hose

4

© SprayTECH.  All rights reserved.

Always use a minimum 12 gauge, three-wire extension

cord with a grounded plug.  Never remove the third prong

or use an adapter.

Preparing a New Sprayer

If this sprayer is new, it is shipped with test fluid in the fluid
section to prevent corrosion during shipment and storage.
This fluid must be cleaned out of the system thoroughly with
mineral spirits before spraying paint.

Always keep the trigger lock on the spray gun in the

locked position while preparing the system.

1. Place the siphon tube into a container of mineral spirits.
2. Place the return hose into a metal waste

container.

3. Move the PRIME/SPRAY valve down to

the PRIME position.

4. Turn on the sprayer and set the pressure

to minimum by turning the pressure control
knob to the “1” or “2” position.

5. Allow the sprayer to run for 15–30 seconds to flush the

test fluid out through the return hose and into the waste
container.

6. Turn off the sprayer by moving the pressure control knob

to the “0” position.

Preparing to Paint

Before painting, it is important to make sure that the fluid in the
system is compatible with the paint that is going to be used.

Always keep the trigger lock on the spray gun in the

locked position while preparing the system.

1. Place the siphon tube into a container of the appropriate

solvent.  Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.

2. Place the return hose into a metal waste container.
3. Move the PRIME/SPRAY valve down to

the PRIME position.

NOTE: Hold the return hose in the waste

container when moving the

PRIME/SPRAY valve to PRIME in

case the sprayer is pressurized.

CAUTION

NOTE: Incompatible fluids and paint may cause the

valves to become stuck closed, which would

require disassembly and cleaning of the

sprayer’s fluid section.

Priming and 

Cleaning Zone 

(minimum PSI)

0 = OFF 

(0 PSI)

Pressure Control Knob

8 = 3100 PSI

(maximum PSI)

CAUTION

CAUTION

All manuals and user guides at all-guides.com

Summary of Contents for 0552060

Page 1: ...637 Order Entry 1 800 443 4500 Fax 1 800 525 9501 www spraytechinc com Owner s Manual NOTE This manual contains important warnings and instructions Please read and retain for reference Model Numbers 0...

Page 2: ...ment is able to result in static electricity Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes All parts of the spray system including the pump hose asse...

Page 3: ...se lowest possible pressure to flush equipment 10 Follow all appropriate local state and national codes governing ventilation fire prevention and operation 11 The United States Government Safety Stand...

Page 4: ...minimum 12 gauge three wire extension cord with a grounded plug Never remove the third prong or use an adapter Preparing a New Sprayer If this sprayer is new it is shipped with test fluid in the flui...

Page 5: ...tal waste container 6 Turn off the sprayer by moving the pressure control knob to the 0 position 7 Remove the return hose from the waste container and place it in its operating position above the cont...

Page 6: ...peed Even coat throughout Approximately 10 to 12 inches WARNING NOTE When spraying block filler mastics or high solid coating remove the gun filter and high pressure filter screens WARNING 6 SprayTECH...

Page 7: ...NG CAUTION WARNING Good spray pattern Paint tailing pattern SprayTECH All rights reserved 7 9 Move the PRIME SPRAY valve up to its SPRAY position 10 Turn on the sprayer and set the pressure to minimum...

Page 8: ...3 Inspect the filter Based on inspection clean or replace the filter 4 Inspect the o ring Based on inspection clean or replace the o ring 5 Slide the new or cleaned filter over the core spring Push th...

Page 9: ...ssembly Housing Gasket Electronic Control Assembly Motor Mounting Screw Electronic Cover Screw Gearbox Housing CAUTION WARNING Replacing the Gears 1 Perform the Pressure Relief Procedure and unplug th...

Page 10: ...rsts until the connecting pin is visible below the slider housing 3 Turn off and unplug the unit Before proceeding follow the Pressure Relief Procedure outlined previously in this manual Additionally...

Page 11: ...n tool over the top of the piston rod 39 Insert the piston rod into the bottom of the cylinder through the lower packing assembly through the upper packing assembly and out through the upper seal reta...

Page 12: ...ervicing the Fluid Section procedure in the Maintenance section of this manual 2 Replace the piston rod following the Servicing the Fluid Section procedure in the Maintenance section of this manual 1...

Page 13: ...cording to the manufacturer s recommendations 1 Rotate the pressure control knob clockwise to increase the pressure setting 2 Reconnect the input voltage for 120V AC Cause 1 The spray tip is too large...

Page 14: ...TION AVERTISSEMENT Fran ais DANGER RISQUES D EXPLOSION OU D INCENDIE Les vapeurs d gag es par le solvant ou la peinture sont explosives et inflammables et peuvent causer des corporels s rieux ou domma...

Page 15: ...ues et responsabilit s lorsqu il utilise des pi ces qui ne sont pas conformes aux caract ristiques techniques minimales ainsi qu aux dispositifs de s curit du fabricant de la pompe V rifier avant tout...

Page 16: ...scape y aire fresco para hacer que el aire que est dentro del rea de atomizaci n se mantenga libre de acumulaciones de vapores inflamables Evite todas las fuentes de ignici n como son las chispas elec...

Page 17: ...a conectada a tierra Todas las mangueras soportes giratorios pistolas y accesorios que se usen con esta unidad deben tener una capacidad de presi n de 3100 lb pulg2 21 4 MPa o mayor No atomice en d as...

Page 18: ...0507773 Jam nut 1 6 0552155 Fluid section assembly 1 7 0507798 Siphon tube 1 8 0507783 Hose clamp 1 9 5006536 Inlet screen 1 Item Part Description Quantity 10 0507786 Lock washer 5 11 0507787 Screw 5...

Page 19: ...art Description Quantity 21 0551628 Fuse holder 1 22 0551627 Fuse 1 23 0507756 Screw 1 24 0507752 Potentiometer mounting plate 1 25 0507749 Nut 1 26 0507748 Cap 1 27 0507740 Pressure control knob 1 28...

Page 20: ...52178 Lower packing assembly 2 6 0552157 Adapter 1 7 0507732 Piston rod 1 8 0507734 Outlet valve seal 1 9 0507452 Outlet valve cage 1 10 0507454 Washer nylon 1 11 9841502 Outlet valve ball 1 12 029451...

Page 21: ...0507774 Screw 4 14 0507655 Cord wrap 2 15 0507379 Wheel 2 16 9890104 Cap 2 1 3 4 2 5 6 9 10 8 7 13 11 12 14 16 15 Filter Assembly 0507203 Item Part Description Quantity 1 0294194 Filter body 1 2 14069...

Page 22: ...ldment includes items 6 and 8 1 Suction Set low boy 1 2 3 4 5 6 Item Part Description Quantity 1 0507964 Return hose 1 2 0507965 Siphon hose 1 3 0507966 Swivel 1 4 5006536 Inlet screen 1 5 0507783 Cla...

Page 23: ...Roller Cover 1 1 4 Nap 0152235 12 Roller Cover 1 2 Nap 0152236 12 Roller Cover 3 8 Nap 0152237 12 Roller Cover 3 4 Nap 0152238 12 Roller Cover 1 1 4 Nap 0093930 Anti Seize Compound 0152909 R 10 Teles...

Page 24: ...NY AND ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW THE DURATION OF ANY IMPLIED WARRANTIES WHICH CAN...

Reviews: