Summary of Contents for AUTOJET 1750+

Page 1: ...AutoJet 1750 Spray Control Panel OWNER S MANUAL ML001750PLUS spray com...

Page 2: ...ay Timing Modes 21 7 4 Fixed Spray Time 22 7 5 Variable Spray Time 24 7 6 Duty Cycle 27 7 7 Trigger 28 7 8 Tank Level Level Sensor 29 8 Faults and Alarms 30 8 1 Faults and Alarms Settings 30 9 Mainten...

Page 3: ...y ATTENTION Supplementary information for the user that draws attention to possible problems 2 1 GENERAL SAFETY INFORMATION READ AND FOLLOW INSTRUCTIONS All safety related and operating instructions s...

Page 4: ...ety precautions when using a pressurized spray system When dealing with pressure applications the system pressure should never exceed the lowest rated component Always know your system all component c...

Page 5: ...spray period start delay and stop delay times The controller is designed to run both electric and air actuated spray nozzles Can drive Spraying Systems Co electric actuated spray nozzles 3 6 amps max...

Page 6: ...w delivered to the target surface This provides better flow control with larger spray tips that are less prone to clogging The droplet size is affected by the pressure of the liquid With PSC the dropl...

Page 7: ...ger interlock or level switch input Trigger Interlock controls the state of run standby mode PLUG AND SPRAY COMPATIBILITY The 1750 can be mounted to the universal frame with mobile cart Plug and Spray...

Page 8: ...NC Viewer 2 Power on the 1750 if system is not already on 3 In Wi Fi settings on your mobile device locate the Wi Fi SSID typically SSCO_xxxxxx Select connect and enter the default password of SSCO175...

Page 9: ...a recipe is selected If you have purchased the optional software upgrade and the desired PWM setpoint is set in the recipe between 1 and 100 depending on your application 3 7 ACTIVATING RECIPES A rec...

Page 10: ...een in Trigger settings Depending on your settings you will have Fixed spray mode Momentary button single shot mode starts a spray when clicked Variable spray mode Toggle button starts stops a spray w...

Page 11: ...s change the language where applicable view system information and view the activity log LANGUAGE Here you will be able to change the language of the user interface text if available ABOUT SCREEN This...

Page 12: ...iew these activity reports on the 1750 or export the activity report via a USB stick Note When the system is started for the very first time and for every reboot thereafter it boots up to default user...

Page 13: ...remain logged in without any activity Setting the value to 0 will leave the user logged in until they choose to log out or the system is rebooted Add new user settings Change Password Allows you to c...

Page 14: ...p Admin There is a fourth factory settings user SSCO that is included with the system in User Group admin This user is included as a backup option to reset User Group cust_admin passwords if they are...

Page 15: ...erclockwise to decrease the pressure When the proper air pressure is reached press down on the knob on the regulator to lock it in place Note Your system is equipped with cylinder air for air actuated...

Page 16: ...o configure most settings if the recipe feature is included in your system configuration 7 1 SPRAY NOZZLE SETTINGS The Nozzle Settings page allows for the editing of the Nozzle type and Cycle Speed No...

Page 17: ...stem will start spraying when it receives a trigger signal and stop when the trigger signal is removed If your system is equipped with an air atomizing nozzle the 1750 will switch the air output on be...

Page 18: ...e closing of the electric spray nozzle duration is dependent on nozzle model and supply volt age Gun Nozzle Offset Offset time in milliseconds The difference in the opening and closing time of the Pul...

Page 19: ...um and maximum cycles per minute as well as the spray thickness Maximum cycles speed is 7 500 cycles min minimum range is 0 60 cycles min Maximum cycle speed Maximum speed that the nozzle should switc...

Page 20: ...settings sections contains four tabs The drop down list near the top of the page allows you to select which recipe you would like to view edit or apply as the current spray parameters The 1750 is capa...

Page 21: ...gnal goes low All delay values can be set from 0 00 to 320 00 sec spray times can be set to 0 01 to 320 00 sec SPRAY PERIOD The spray period is the time the object remains under the spray nozzle or th...

Page 22: ...pray pattern if the start delay is too short In this case the start delay will be extended as required to provide a correct anticipator time This is particularly useful when the start delay may not be...

Page 23: ...er than the spray time then there is an overlap of two successive spray pulses FIXED SPRAY TIME WITH REPEAT SPRAY This timing mode is used to create a continuous repetition of spray period for a fixed...

Page 24: ...he object sensor and the spray nozzle Variable spray period INCREASE SPRAY PERIOD Decrease Start delay The spray is started before the object has reached the spray nozzle Increase Stop delay The spray...

Page 25: ...elay times OVERLAPPING SPRAY EVENTS If spray events overlap the overlapping event will be ignored and the system will continue to spray to ensure the objects are sprayed correctly This situation may o...

Page 26: ...RAY PERIOD This timing mode is used to create a delayed spray pulse of an unknown period when receiving a trigger signal The start and stop delays are typically the distance between the object sensor...

Page 27: ...to control Set the value at 20mA to be 100 or another value depending on your trigger source Sensor Offset The minimum level of the sensor offset can control usually starting from 0mA or 4mA Set the s...

Page 28: ...ill place a trigger button on the home screen that must be pressed every time the system needs to be triggered DI2 Trigger is activated via the Trigger Connection DI2 DI4 DI4 is the trigger interlock...

Page 29: ...turned on and level is low this will toggle on Invert signal If you have a normally open level switch open until liquid level goes low do not turn this on if you are using a normally closed float tog...

Page 30: ...ion on the alarm history screen Once the fault has been corrected complete a power cycle of the 1750 to reset and clear the fault Pressing the orange reset button in the top right hand corner of the s...

Page 31: ...list and your Spray Specialist s Tech contact information SCHEDULER TAB The Scheduler tab will show all upcoming PMs Preventative Maintenance PMs will show the date of next occurrence and are able to...

Page 32: ...ray Specialist can be found by selecting the Spray Specialist tab These editable boxes contain the name phone number and email address of your Spray Specialist TROUBLESHOOTING The 1750 provides troubl...

Page 33: ...s Internal temperature too high The temperature in the module is too high Provide sufficient cooling in the cabinet where the module is located 1s High Voltage The voltage on the Vin input is higher t...

Page 34: ...Check the panel for any loose wires Locate the fuse holder to the right of the power supply and lift the tab on the top of the fuse holder exposing the fuse Due to the type of fuse used a qualified el...

Page 35: ...ated If this does not occur then ensure that the trigger device is properly wired If problem still occurs then consult the manufacturer s manual for the trigger device For electrically actuated spray...

Page 36: ...r M12 3 pin male ELECTRICAL JUNCTION BLOCK If multiple PulsaJet or AA250 electric spray nozzles are used the system comes complete with a junction block to con nect the spray nozzles to the unit The j...

Page 37: ...ffering it should work in most cases SPECIFICATIONS Kit number 040TS04000014W0 Photoelectric sensor Infrared direct reflection sensor with cable connector and bracket NPN NO NC 35 inch 900 mm sensing...

Page 38: ...present to spray This input always goes to 0V pin 3 To activate this feature on the HMI go to settings trigger and pick trigger source DI2 DI4 For the level switch option DI1 this feature allows you...

Page 39: ...cables and the splitter The thru beam has a sensor and a receiver Each gets a cable connecting it to the splitter Then the splitter has a cable to connect it to the system The receiver goes to port 1...

Page 40: ...o signal your system when a fault has occurred in the operation of the spray control panel for example a level sensor going low or a short in one of the nozzle cables To use this fea ture you need to...

Page 41: ...le trunk male M12 1m whip 2 branches x M12 female coupling nuts TPU parallel wiring Part number LE00M12WYE1M Cable Main M12 M x Flying Leads 16 4 ft 5 m cord length bare leads M12 4 pin M 4 wire Part...

Page 42: ...drop we recommend keeping the cable length to a reasonable length Never attempt to chain more than four 4 cables together Electric spray nozzle speed and performance will suffer Part number LEXXSD4FD...

Page 43: ...he black and blue wires dry contacts polarity not important carefully cut back and tape the brown and white wires Run the cable back to the spray control panel and plug into the port labeled T Int Act...

Page 44: ...ngth Mini DIN M12 3 pin male LE00M12MMDIN3MU PulsaJet Nozzle Cable Main 3m cord length M8 3 pin female M12 3 pin male LEXXSD3M83F030P Trigger Cable Trig 5 m cord length flying leads M12 4 pin female L...

Page 45: ...ability function or design Other company and product names may be trademarks of their respective companies Warranty is one 1 year on non wear parts from ship date Wear items are covered for manufactur...