48
MAINTENANCE
Error Messages (Continued)
Main
Code X
Secondary
Code Y
Error message
Note
4
3
DC_BUS`s tension
is overloaded.
5
1
Forced to warm up.
5
2
Forced to EngStop
6
1
Generator`s current
is overloaded.
6
2
Generator is failure
in voltage
6
3
Generator`s
temperature is too
high.
7
1
L/R stride motor over
current or positioning
error being detected
while the motor is
running in exercise
mode.
The stride motor stops,
but other functions of
the elliptical trainer still
work. Turn off the main
power, switch off the
motor and its driver
circuit .
7
2
Right stride length
error
The “SELECT
PROGRAM” screen
will show ERROR_7_4
when detecting
abnormal situations on
L/R stride motor.
7
3
Left stride length
error
7
4
L/R stride motor
abnormality being
detected when
power on.
8
1
When start up,
communication with
the drive board is
abnormal.
Will restore when the
communication is back
to normal.
8
2
When start up,
communication with
the driver board
is normal, but an
abnormality occurs
during use.