Flow-X─ Function Reference
4-97
Flow-X General functions - fxAPI_Gravity60F_1980
truncating rules are applied.
The compressibility factor F is
rounded to 3 decimal places as
specified in the standard.
Equilibrium
pressure
The equilibrium pressure is
considered to be 0 psig for liquids
which have an equilibrium pressure
less than atmospheric pressure (in
compliance with API MPMS 12.2 par.
12.2.5.4)
psig
EQUIPR
ES
0..2000
0
Conversion
method
1: From observed to standard
conditions
2: From standard to observed
conditions
CONVE
RSION
1
Function
outputs
Remark
EU
SW tag
Alarm
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
3: No convergence
-
STS
FIOOR
CALC
NOCONV
1
Output API
gravity
Depending of the conversion
method this represents the API
gravity at either at 60
°
F and the
equilibrium pressure or the
observed temperature and
pressure
°API
API
0
CTL
Volume correction factor for
temperature.
Value will be rounded according to
input 'API2540 rounding'
-
CTL
1
CPL
Volume correction factor for
pressure
Value will be rounded according to
input 'API 11.2.1 rounding'''
-
CPL
1
CTPL
Combined volume correction
factor
CTPL = CTL * CPL
-
CTPL
1
K0
Actual value of constant K0 used
for CTL calculation
-
K0
0
K1
Actual value of constant K1 used
for CTL calculation
-
K1
0
K2
Actual value of constant K2 used
for CTL calculation
-
K2
0
Alpha
Thermal expansion factor
1/°F
ALPHA
0
F
Compressibility factor
-
F
0
Product
When input 'Product' is 'B - Auto
select', then the output is set to
the actual selected product of
table 5B / 6B (enumerative value
as defined for input 'Product'), else
the output is set equal to input
'Product'.
-
PRDCUR
0
CTL calc out of
range
With respect to the standard used
for the calculation of CTL the
combination of input values is:
0: In Range
1: Out of Range
CTLOOR
0
CPL calc out of
With respect to the standard used
0
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...