Flow-X─ Function Reference
4-125
Flow-X General functions - fxAPI_Table5_1952
fxAPI_Table5_1952
°API (T) --> °API (60°F)
This function converts an API gravity value at the observed temperature to the API gravity value at 60°F
in accordance with API 1952 Table 5.
Compliance
ASTM-IP Petroleum Measurement Tables, American Edition, United States Units of
Measurement, 1952
Function inputs
Remark
EU
SW
tag
Range
Defaul
t
Name
Optional tag name, tag description
and tag group
Observed API
Observed API gravity
°API
-20..120
0
Observed
temperature
Temperature at which the API gravity
is observed
°F
-100..400
60
Function
outputs
Remark
EU
SW tag
Alarm
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
3: No convergence
-
STS
FIOOR
CALCERR
NOCONV
1
API at 60 °F
API gravity at 60°F
°API
API
0
Calculation out
of range
With respect to the standard the
input values are:
0: In Range
1: Out of Range
-
OOR
0
Calculations
The table values are the standard, so no calculations are involved. The function performs an
interpolation between the table values that correspond to the input values.
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...