Flow-X─ Function Reference
4-131
Flow-X General functions - fxAPI_Table6_1980
fxAPI_Table6_1980
°API (60°F, 0 psig) --> CTL
This function calculates the volume correction factor for temperature from the API gravity value at 60°F
and the observed temperature.
The temperature conversion is according to API-2540, Tables 6A (Generalized Crude Oils) and 6B
(Refined Oil Products) and API MPMS 11.1 Chapter XIII Table 6D: 1984 (Lubricating Oils).
Compliance
API MPMS 11.1 Volume X (API Standard 2540) - Table 6A - Generalized Crude Oils,
Correction of Volume to 60°F against API Gravity at 60°F - First Edition, August 1980
API MPMS 11.1 Volume X (API Standard 2540) - Table 6B - Generalized Products, Correction
of Volume to 60°F against API Gravity at 60°F - First Edition, August 1980
API MPMS 11.1 Volume XIII - Table 6D - Generalized Lubricating Oils, Correction of Volume
to 60°F Against API Gravity at 60°F - January 1982
Function inputs and outputs
Function inputs
Remark
EU
SW tag
Range
Default
Name
Optional tag name, tag
description and tag group
API at 60 °F
API gravity at 60°F and the
equilibrium pressure
°API
-20..120
0
Observed
temperature
°F
-100..400
60
Product
1: A - Crude Oil
2: B - Auto select
Selection based on °API at 60 °F
3: B - Gasoline
4: B - Transition Area
5: B - Jet Fuels
6: B - Fuel Oil
7: D - Lubricating Oil
PRDTYP
-
1
API2540 rounding
0: Disabled
The calculations are
performed with full precision
and the final CTL value is
rounded as specified by
input 'CTL decimal places'
1: Enabled for computational
value
API-2540 rounding and
truncating rules are applied
and the computational value
for CTL as specified in the
standard is used, meaning
that the CTL value has:
4 decimal places if CTL >=1
5 decimal places if CTL < 1.
2: Enabled for table value
API-2540 rounding and
truncating rules are applied
and the table value for CTL
as specified in the standard
meaning that the CTL value
has 4 decimal places in all
APIROUN
D
-
0
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...