Appendix A: Landslide Test Server NIC Configurations
Supported NIC Configurations and Port Names
Spirent Landslide Test System Installation Guide
|
59
C100-M2 and Earlier Test Server Supported NIC Configurations
The following tables describe the NIC configurations that are supported on the C100-M2
and earlier test servers.
Notes: •
Slot 6 is unused.
•
L-ACC-006 Legacy IPSec accelerator card is optional for all configurations.
Table A-13.
One, two, three or four quad-port 1 Gbps NICs, 4x, 8x, 12x, or 16x 1 Gbps
ports (L-ACC-006 IPSec Accelerator Card optional)
Slot
Card
Ports
1
Third quad-port, 1 Gbps
eth10, eth11, eth12, eth13
2
First quad-port, 1 Gbps
eth2, eth3, eth4, eth5
3
Second quad-port, 1 Gbps
eth6, eth7, eth8, eth9
4
Fourth quad-port, 1 Gbps
eth14, eth15, eth16, eth17
5
Optional L-ACC-006 IPSec
Accelerator
NA
Table A-14.
One dual-port 10 Gbps NIC and one, two or three quad-port 1 Gbps NICs, 2x
10 Gbps ports and 4x, 8x or 12x 1 Gbps ports (L-ACC-006 IPSec Accelerator
Card optional)
Slot
Card
Ports
1
Second quad-port, 1 Gbps
eth8, eth9, eth10, eth11
2
Dual-port, 10 Gbps (AONIC)
eth2, eth3
3
First quad-port, 1 Gbps
eth4, eth5, eth6, eth7
4
Third quad-port, 1 Gbps
eth12, eth13, eth14, eth15
5
Optional L-ACC-006 IPSec
Accelerator
NA
Summary of Contents for Landslide C100
Page 1: ...P N 71 008573 REV A Installation Guide Spirent Landslide Test System October 2018 ...
Page 12: ...12 Spirent Landslide Test System Installation Guide ...
Page 16: ...16 Spirent Landslide Test System Installation Guide ...
Page 44: ......
Page 48: ...48 Spirent Landslide Test System Installation Guide ...