Initial Installation
Management Port Configuration
Spirent Landslide Test System Installation Guide
|
27
14
The user will be prompted to configure the alternate IPv4 Address mode for any
desired services that may require the use of IPv4. For example, if IPv4 addresses were
used in provisioning NTP or PTP in the steps above, configuration of the IPv4
Address mode is required. If no alternate IPv4 management interface is desired or
needed, press
Enter
to accept the default value
none
to skip this step. Otherwise,
specify
static
or
dynamic
to continue with configuring an alternate IPv4 management
address.
Configure <TAS / TS / TAS+TS> alternate IPv4 Address mode
(none/static/dynamic) [none]:
If
static
is selected, answer the resulting configuration prompts.
•
Specify a unique IPv4 address for the alternate IPv4 management address then
press
Enter
to continue.
<
port
> <
TAS / TS / TAS+TS
>
IPv4 Address []:
•
Specify the IPv4 network mask, then press
Enter
to continue.
<
port
> <
TAS / TS / TAS+TS
>
IPv4
Network Mask []:
•
Specify the address for the IPv4 gateway in your network, then press
Enter
to
continue.
<
port
> <
TAS / TS / TAS+TS
>
IPv4 IP Gateway []:
The initial configuration is complete at this point. Type
yes
and press
Enter
to reboot
the system.
System must be rebooted for these changes to take effect…
Reboot now? (yes/no) [yes]:
Note:
If errors are detected in any of the data entered above, answer
no
to the reboot
question and rerun the
ipcfg
command.
Summary of Contents for Landslide C100
Page 1: ...P N 71 008573 REV A Installation Guide Spirent Landslide Test System October 2018 ...
Page 12: ...12 Spirent Landslide Test System Installation Guide ...
Page 16: ...16 Spirent Landslide Test System Installation Guide ...
Page 44: ......
Page 48: ...48 Spirent Landslide Test System Installation Guide ...