Initial Installation
Management Port Configuration
Spirent Landslide Test System Installation Guide
|
25
5
Use the
cfguser
account to telnet or login via console to a Landslide platform. The
default password is the same as the user name.
login: cfguser
password: cfguser
6
The first time the cfguser user logs into Landslide, the user should be prompted to
define the initial network configuration.
Management port and TAS IP may not be configured on this
machine.
Configure now? (y/n)
Type
y
and press
Enter
to define the configuration.
If the initial configuration question does not display, type
ipcfg
at the command
prompt.
!
Caution: •
Do not abort this script when it is executed for the first time on a new
platform. Background processes configure the services that should
automatically start on boot. If the script is aborted, some services,
including telnet, will not start if the platform is power-cycled or rebooted.
•
Do not use arrow keys or the Delete key to correct data entry errors;
instead, use only the
Backspace
key. If errors are detected after data has
already been entered, at the end of the script, answer
no
to the reboot
question and rerun the
ipcfg
command.
7
A warning will be displayed, and the user will be asked if they wish to continue. Type
yes
and press
Enter
to continue.
Note: Do not terminate this utility, otherwise it can lead to
system instability! Do you wish to Continue (yes/no) [no]:
8
The user will be prompted to identify the port to be used as the management port. The
user must specify eth0v6 as the management port for IPv6 management. Specify
eth0v6
and press
Enter
to continue.
NOTE - Preferred management port is eth0
Designate management port (eth0/eth0v6 --eth17/eth17v6)
[eth0]:
9
The user will be prompted to answer a set of configuration prompts for the
management port. The port name is shown in the prompt and is enclosed in angle
brackets <eth0v6>.
•
Specify a unique IPv6 address for the management port, then press
Enter
to
continue.
<
port
>
IPv6 Address []:
•
Specify the IPv6 network mask in slash notation - i.e. /64, then press
Enter
to
continue.
<
port
>
IPv6 Network Mask []:
•
Accept the default configuration to enable automatic speed and duplex
negotiation by pressing
Enter
to continue.
Auto Negotiate? (yes/no) [yes]:
Summary of Contents for Landslide C100
Page 1: ...P N 71 008573 REV A Installation Guide Spirent Landslide Test System October 2018 ...
Page 12: ...12 Spirent Landslide Test System Installation Guide ...
Page 16: ...16 Spirent Landslide Test System Installation Guide ...
Page 44: ......
Page 48: ...48 Spirent Landslide Test System Installation Guide ...