61 Operations Manual
–
Wall Extruder (Frame Nailer Gen IV and Tables)
Clamps not activating
Air supply
Replace any broken air lines
Damaged linear bearing rails
Replace linear rails
Obstruction
Clear obstruction
Clamps ineffective/inadequately
clamping
Lack of lubrication
Lubricate moving parts
Damaged air lines
Check for bent or leaking air lines, and
replace as required
Loose, damaged, or missing
parts
Inspect clamp parts. Repair or replace
items as required
Pneumatic cylinders
ineffective/inadequately
performing
Blocked air lines
Check for blockages. Flush system if
required
Damaged air lines
Check for bent or leaking air lines, and
replace as required
Loose, damaged, or missing
parts
Inspect cylinder parts. Repair or replace
items as required
Nails being punched too far into
the timber
Excessive air pressure
Adjust the regulator to the correct
pressure
Nail heads protruding from the
timber
Low air pressure
Adjust the regulator to the correct
pressure
If any of the above corrections do not solve the issue, then do not use the Wall Extruder and
contact a supervisor, maintenance engineer, or Spida Machinery.