Malfunctions

Thermo E 200/320

60

Table: Flash codes

No. of

pulses

Malfunction

Description

0

CD malfunction

Control device malfunction

1

No start within safety time

No start within safety time

2

Flame interruption

Flame interruption during burner operation, restart 
unsuccessful

3

Overvoltage / undervoltage

Overvoltage
Undervoltage

4

Unexpected light detection in initial or purge cycle

Unexpected light (flame guard bright in purge cycle 2)
Unexpected light (flame guard bright before ignition)

5

Flame guard defective

Flame guard short-circuited
Flame guard disconnected

6

Temperature sensor / overheating protection defective

Temperature sensor short-circuited
Temperature sensor disconnected
Temperature sensor / overheating protection implausible
Overheating protection short-circuited
Overheating protection disconnected

7

Solenoid valve defective

Solenoid valve short-circuited
Solenoid valve disconnected

8

Burner Motor / Nozzle block pre-heater defective

Burner Motor short-circuited

9

Circulating pump defective

Circulating pump short-circuited

10

Overheating protection has tripped

Overheating T>125°C

11

Electronic ignition unit defective

Electronic ignition unit short-circuited
Electronic ignition unit disconnected

12

Heater lock-out

Flame interruption counter threshold reached
Heater lock-out - release required
Malfunction counter threshold reached

Summary of Contents for Thermo E 200

Page 1: ...Wasser Heizger te Water Heaters Calefactores de agua Einbauanweisung Installation Instructions Instrucciones de montaje Thermo E 200 Thermo E 320 Stand 11 2012 Ident Nr 11114270C II...

Page 2: ...ion of the circulating pump 40 6 Operation indication 46 7 Connection to the vehicle cooling system 47 8 Fuel Supply 48 9 Combustion air supply 49 10 Exhaust pipe 50 11 Electrical connections 51 12 In...

Page 3: ...er Verfahren zur Besch digung von Bauteilen f hren kann HINWEIS Diese berschrift wird benutzt wenn auf eine Besonderheit aufmerksam gemacht werden soll In this Installation Instruction sections highli...

Page 4: ...ndo la observaci n inexacta o la no observaci n de instrucciones o procedimientos puede resultar en lesiones o accidentes mortales ATENCI N Este t tulo se usa cuando la observaci n inexacta o la no ob...

Page 5: ...Vorschriften des Absatzes 5 3 entsprechen 5 3 2 Anordnung des Heizger ts 5 3 2 1 Teile des Aufbaus und andere Bauteile in der N he des Heiz ger ts m ssen vor berm iger Erw rmung und einer m glichen V...

Page 6: ...kann 5 3 6 Heizlufteinlass entf llt 5 3 7 Heizluftauslass entf llt 5 3 8 Automatische Steuerung des Heizungssystems 5 3 8 1 Beim Absterben des Motors des Fahrzeugs muss das Heizungssystem automatisch...

Page 7: ...der CO2 Einstellung bei uneingeschr nktem Heizbetrieb bis 1 500m ber NHN einsetzbar bis 2 000m ber NHN auch bei kurzzei tigem Aufenthalt Pass berquerungen Rastzeiten Bei dauerhaftem Einsatz oberhalb...

Page 8: ...teuerger t und Temperatursensor ist unzul ssig und f hrt zum Erl schen jeglicher Gew hr leistungsanspr che 3 1 Einbauort Auf die Einbaugegebenheiten des jeweiligen Fahrzeugtyps ist zu achten Das Heizg...

Page 9: ...00 320 593 247 70 4 2 5 8 6 7 1 3 190 38 110 ca 224 232 303 386 242 51 ca 440 1 Brennlufteintritt 2 Abgasaustritt 3 Brennstoffeintritt 4 Brennstoffaustritt 5 K hlfl ssigkeitseintritt 6 K hlfl ssigkeit...

Page 10: ...s gut sichtbar sein oder Typschild Duplikat verwenden HINWEIS Das Jahr der ersten Inbetriebnahme muss auf dem Typschild des Heiz ger tes durch Entfernen der nicht zutreffenden Jahreszahlen dauerhaft g...

Page 11: ...baubeispiel f r Heizger t 1 Wandheizk rper mit Gebl se 2 W rmetauscher Einstieg 3 Heizger t 4 Umw lzpumpe 5 Dachw rmetauscher 6 Kraftfahrzeugmotor 7 Fahrerplatzheizung 8 Bedienelement Vorlauf R cklauf...

Page 12: ...en verwendet werden sollen die nicht in dieser Einbauanweisung spezifiziert sind ist sicherzustellen dass deren Dauer Stromaufnahme 8 75A nicht bersteigt Wird der Ausgang f r die Umw lzpumpe am Steuer...

Page 13: ...pe U 4814 Aquavent 5000 Bild 6 Umw lzpumpe U 4814 Einbaulage Sw Br Bild 7 Lochbild f r St nder Umw lzpumpe U 4814 Bild 8 Volumenstrom und Durchflu widerstand Umw lzpumpe U 4814 Volumenstrom mit Wasser...

Page 14: ...zum Verschlei der Anlaufscheibe am Laufrad Bild 9 Umw lzpumpe U 4854 Einbaulage 5 min 0 90 249 53 31 110 38 225 32 60 99 5 38 23 131 5 Sw Br 0 85 Bild 10 Lochbild f r St nder Umw lzpumpe U 4854 Bild...

Page 15: ...60 0 90 0 85 min 5 32 23 224 2 38 38 Bild 13 Lochbild f r St nder Umw lzpumpe U 4855 Bild 14 Volumenstrom und Durchflu widerstand Umw lzpumpe U 4855 1 1 1 0 0 9 0 8 0 7 0 6 0 5 0 4 0 3 0 2 0 1 Q 1000...

Page 16: ...h f hrt zum Verschlei der Anlaufscheibe am Laufrad Bild 15 Umw lzpumpe U 4856 Einbaulage 38 38 31 53 126 229 2 23 32 60 115 0 90 0 85 min 5 Bild 16 Lochbild f r St nder Umw lzpumpe U 4856 Bild 17 Volu...

Page 17: ...tor ber den Fehlermodus nach ca 1 s abgeschaltet Dreht der Motor trotz Bestromung in 1 s keine ganze Umdrehung wird ebenfalls ber den Fehlermodus abgeschaltet 5 5 4 Fehlermodus ber den Fehlermodus wir...

Page 18: ...m einen der reine Schaltermodus und zum anderen der Blinkmodus Im Blinkmodus dient dieser Ausgang der Ausgabe des Fehlerblinkcodes ber die Betriebsanzeige Signalisiert werden zwei Funktionen a Ger t i...

Page 19: ...ei einem separaten Heizkreislauf d rfen nur berdruckventile mit einem ffnungsdruck von maximal 2 bar verwendet werden Vor der ersten Inbetriebnahme des Heizger tes oder nach Erneuerung der K hlfl ssig...

Page 20: ...u enmantel des Heizger tes kann bei Betrieb ohne K hlmittel die Z ndtemperatur von Dieselkraftstoff erreichen Leitungen sind vor Steinschlag zu sch tzen Abtropfender oder verdunstender Kraftstoff darf...

Page 21: ...ge Leitungsl nge 1 5 m ohne Abgasverl ngerung Gesamtl nge von Brennluftansaug und Abgasleitung max 2 10 m Maximal zul ssige Biegungen 270 Zul ssige Abmessungen der Brennluftansaugleitung Thermo E 320...

Page 22: ...r Abgasleitung Thermo E 200 Innendurchmesser 70mm Max zul ssige Leitungsl nge 0 60 m ohne Brennluftansaugver l ngerung Gesamtl nge von Brennluftansaug und Abgasleitung max 2 10 m ACHTUNG Die ffnung de...

Page 23: ...ung zum Heizger t er folgt incl Umw lzpumpe mit F1 25A Die Leitung f r den Eingang des Hauptschalters ist mit 5A abzusichern Der zu verwendende Gegenstecker kann inklusive der erforderlichen Kontakte...

Page 24: ...l 30 Kl 31 HS BA HS BA Heizger t Thermo E BM UP UP UP DVW optional MV C P T 3pin 1 2 3 4 1 2 ZFG Steuerger t 2pin 2pin 4pin 6pin 2 5mm 2 5mm 2 5mm 0 75mm 0 75mm 2 5mm K hlmittel Temperatursensor berhi...

Page 25: ...Thermo E mit Vorwahluhr 1531 Legende siehe Seite 22 K hlmittel Temperatursensor berhitzungsschutz 1 2 Heizger t Thermo E Steuerger t Leitungsquerschnitte gelten f r eine maximale Leitungsl nge von bis...

Page 26: ...funkengeber Legende zum Systemschaltplan C Zum Fahrzeug Power T Temperatur Sensorik C1 Hauptschalter T1 Temperatursensor C2 KL 31 T2 berhitzungsschutz C3 Betriebsanzeige T3 Masse C4 KL 30 V D senstock...

Page 27: ...rkreislauf sowie das Brennstoffversorgungssystem sorgf ltig zu entl ften Dabei ist eine Bef llung der Saugleitung und des Brennstofffilters des Heizger tes zwingend erforderlich Spheros empfiehlt die...

Page 28: ...Brennluftmotor Umw lzpumpe Z ndfunkengeber Magnetventil Zeit in s 12 1 0 15 5 30 90 12 1 0 15 5 30 90 12 1 0 15 5 30 90 Zustand Look for Vorlauf mit Fremdlichtabfrage Vorz ndung Z ndung Stabilisierun...

Page 29: ...icearbeiten sind entsprechend den Anweisungen des Werkstatthandbuches durchzuf hren HINWEIS Die Steckh lsengeh use lassen sich leichter vom Steuerger t l sen wenn sie zun chst fester auf das Steuerger...

Page 30: ...rneutes Einschalten des Hauptschalters HS 2 Reset des Steuerger ts Neuinitialisierung des Steuerger ts z B durch Unterbrechung der Stromversorgung Zus tzlich zur St rverriegelung erfolgt eine Heizger...

Page 31: ...ung kann nun durch erneute Unterbrechung der Stromversorgung f r mindestens 5s innerhalb der n chsten 2min gel scht werden Unterbrechung der Stromversorgung z B durch Ziehen der Sicherung Stecker C am...

Page 32: ...Unterbrechung 6 Temperaturf hler berhitzungsschutz defekt Temperatursensor Kurzschluss Temperatursensor Unterbrechung Temperatursensor berhitzungsschutz unplausibel berhitzungsschutz Kurzschluss berh...

Page 33: ...nstoff Nur der auf dem Typschild des Heizger tes angegebene Brennstoff Dieselkraftstoff gem DIN EN 590 darf verwendet werden Es gelten die Einsatzgrenzen der Norm d h Winterdiesel bis 20 C Arcticdiese...

Page 34: ...rs l 1 8 Mindestwasserumsatz l h 2400 200 2700 200 Mindestmenge des K hlmittel Kreislaufs l min 25 0 CO2 im Abgas bei Nennspannung Vol 9 5 0 5 10 0 0 5 0 8 CO2 im Abgas mit Applikation bei Nennspannun...

Page 35: ...vent 6000SC Volumenstrom I h 5000 gegen 0 2 bar 5000 gegen 0 2 bar 6000 gegen 0 4 bar 6000 gegen 0 4 bar Nennspannung V 12 oder 24 24 24 24 Betriebsspannungsbereich V 20 28 20 28 20 28 20 28 Nennleist...

Page 36: ...Technische Daten Thermo E 200 320 32...

Page 37: ...of combustion heater 5 3 2 1 Body sections and any other components in the vicinity of the heater must be protected from excessive heat and the possibility of fuel or oil contamination 5 3 2 2 The com...

Page 38: ...off automatically and the supply of fuel must be stopped within five seconds when the vehicle s engine stops running If a manual device is already activated the heating system can stay in operation AT...

Page 39: ...djustment up to an altitude of 1500 m above MSL and up to 2000 m above MSL if that is a short stay in such conditions pass crossing break In case of a permanent heater operation above 1500 m up to 200...

Page 40: ...e and temeperature sensor is not permitted and will lead to the loss of all liability claims 3 1 Installation location Consider the installation situation of the relevant vehicle type The heater and c...

Page 41: ...rmo E 200 320 heaters 593 247 70 4 2 5 8 6 7 1 3 190 38 110 ca 224 232 303 386 242 51 ca 440 1 Combustion air intake 2 Exhaust outlet 3 Fuel inlet 4 Fuel outlet 5 Coolant inlet 6 Coolant outlet 7 Temp...

Page 42: ...ible when the heater is installed otherwise a duplicate model plate must be used NOTE The year of the initial operation must be durably marked by removing the year numbers that are not applicable Fig...

Page 43: ...ation example for the heater 1 Wall heater with blower 2 Heat exchanger at entry 3 Heater 4 Circulating pump 5 Roof heat exchanger 6 Vehicle engine 7 Driver s position heating system 8 Control element...

Page 44: ...y If circulating pumps are used which are not specified in this In stallation Instruction make sure their permanent current con sumption not exceeds 8 75A If the circulating pump output at the control...

Page 45: ...ump U 4814 Aquavent 5000 Fig 6 Circulating pump U 4814 Installation position Sw Br Fig 7 Hole pattern for the U 4814 circulating pump stand Fig 8 Delivery rate and flow resistance U 4814 circulating p...

Page 46: ...l h will result in undue wear of the wearing disc of the impeller Fig 9 Circulating pump U 4854 Installation position 5 min 0 90 249 53 31 110 38 225 32 60 99 5 38 23 131 5 Sw Br 0 85 Fig 10 Hole patt...

Page 47: ...0 8 52 8 98 115 60 0 90 0 85 min 5 32 23 224 2 38 38 Fig 13 Hole pattern for the U 4855 circulating pump stand Fig 14 Delivery rate and flow resistance U 4855 circulating pump 1 1 1 0 0 9 0 8 0 7 0 6...

Page 48: ...an 2500 l h will result in undue wear of the wearing disc of the impeller Fig 15 Circulating pump U 4856 Installation position 38 38 31 53 126 229 2 23 32 60 115 0 90 0 85 min 5 Fig 16 Hole pattern fo...

Page 49: ...e motor is switched off after approx 1 second by the error mode If the motor does not complete a whole rev olution within 1 second despite the power supply it will also be shut down by the error mode...

Page 50: ...wo display modes First the pure switching mode and further a flashing mode In the flashing mode this output displays the error flash codes by the operation indication Two functions are indicated a the...

Page 51: ...eating circuit only pres sure control valves with an opening pressure of max 2 bar may be used Before the heater is started up for the first time or after the coolant has been replaced it must be ensu...

Page 52: ...ithout coolant the outer shell of the heater may reach a temperature equalling the ignition tem perature of diesel fuel The lines must be protected from stone damage Any dripping or evaporating fuel m...

Page 53: ...ombustion air intake line and exhaust gas line max 2 10 m Max permissible bends 270 Permissible dimensions of the combustion air intake line Thermo E 320 Inside diameter 55 mm Max permissible line len...

Page 54: ...of the exhaust pipe Thermo E 200 Internal diameter 70mm Max permissible pipe length 0 60 m without combustion air intake extension Total length of combustion air intake line and exhaust pipe max 2 10...

Page 55: ...used according to DIN 72581 part 3 The power supply circuit of the heater incl circulating pump is to be protected by F1 25A The main switch wire is to be protected using a 5A fuse The required mating...

Page 56: ...A T 30 T 31 MS OI Main Switch Operating Indicator Heater Thermo E BM CP CP CP NPH optional SV C P T 3pin 1 2 3 4 1 2 EIU Control Device 2pin 2pin 4pin 6pin 2 5mm 2 5mm 2 5mm 0 75mm 0 75mm 2 5mm Coolan...

Page 57: ...timer 1531 legend see page 54 1 2 Heater Thermo E T 58 T 30 T 30 T 31 T 31 MS CP CP CP OI T 15 Coolant Temperature Sensor Overheating Protection Pre Selection Timer 1531 Control Device NPH EIU SV Cabl...

Page 58: ...iagram C To vehicle Power T Temperature sensors C1 Main switch T1 Temperature sensor C2 Terminal 31 T2 Overheating protection C3 Operation indicator T3 Ground C4 Terminal 30 V Nozzle block pre heating...

Page 59: ...ns are used After heater installation bleed the water system and the fuel supply sys tem carefully In this process it is mandatory to fill the suction line and the fuel filter of the heater completely...

Page 60: ...ng pump Electronic ignition unit Solenoid valve Time in seconds 12 1 0 15 5 30 90 12 1 0 15 5 30 90 12 1 0 15 5 30 90 Condition Look for Initial cycle with light check Pre Ignition Ignition Stabilizat...

Page 61: ...maintenance is to be performed in accordance to the instruc tions contained in the Workshop Manual NOTE The receptacles can be detached easier from the control device by pres sing them first firmer on...

Page 62: ...defined time period extrinsic light Variants to reset the heater after a fault lock out 1 Switch off the main switch MS and then turn it on again 2 Reset the control device e g through disconnecting...

Page 63: ...e heater lock out can be released if the power supply for at least 5 sec within the next 2 min is interrupted again Power supply interruption for example by remove the fuse disconnect the connector C...

Page 64: ...re sensor overheating protection defective Temperature sensor short circuited Temperature sensor disconnected Temperature sensor overheating protection implausible Overheating protection short circuit...

Page 65: ...specified fuel Diesel fuel acc to DIN EN 590 must be used The operation limits as per this standard must be adhered to that means winter diesel up to 20 C arctic diesel up to 40 C ATTENTION The above...

Page 66: ...exchanger l 1 8 Minimum water flow l h 2400 200 2700 200 Minimum capacity of the water system l min 25 0 CO2 in exhaust gas at rated voltage Vol 9 5 0 5 10 0 0 5 0 8 CO2 in exhaust gas with applicati...

Page 67: ...nt 6000SC Delivery rate I h 5000 against 0 2 bar 5000 against 0 2 bar 6000 against 0 4 bar 6000 against 0 4 bar Rated voltage V 12 or 24 24 24 24 Operating voltage range V 20 28 20 28 20 28 20 28 Rate...

Page 68: ...Technical data Thermo E 200 320 64...

Page 69: ...situados cerca del calefactor deber n protegerse contra un calentamiento excesivo y contra una posible contaminaci n con combustible o aceite 5 3 2 2 El calefactor de combusti n no debe representar p...

Page 70: ...ema de calefacci n debe desconectarse autom ticamente y la alimentaci n de combustible debe interrumpirse en el plazo de cinco segundos Si ya se encuentra activada una instalaci n de control manual el...

Page 71: ...alefacci n sin restricciones hasta 1 500m por encima del nivel del mar incluso hasta una altitud de 2 000m por encima del nivel del mar en permanencias cortas puertos de monta a pausas de descanso Par...

Page 72: ...temperatura no est permitido y cualquier contravenci n resultar en la extinci n de todos los derechos de garant a 3 1 Emplazamiento de instalaci n Se deber n tener en cuenta las circunstancias de mon...

Page 73: ...3 190 38 110 ca 224 232 303 386 242 51 ca 440 1 Entrada del aire de combusti n 2 Salida del gas de escape 3 Entrada de combustible 4 Salida de combustible 5 Entrada de l quido refrigerante 6 Salida d...

Page 74: ...puesta en servicio deber marcarse claramente en la placa de caracter sticas del calefactor suprimiendo los a os que no correspondan Figura 2 Posici n de montaje Figura 3 Ilustraci n de agujeros 320 11...

Page 75: ...de pared con ventilador 2 Intercambiador de calor en la entrada 3 Calefactor 4 Bomba de circulaci n 5 Intercambiador de calor en el techo 6 Motor del veh culo 7 Calefacci n del puesto de conductor 8 E...

Page 76: ...especificadas en este manual de instalaci n deber asegurarse de que su consumo permanente de corriente no exceda de 8 75A Si la salida para la bomba de circulaci n en la unidad de control no se requi...

Page 77: ...Aquavent 5000 Figura 6 Bomba de circulaci n U 4814 Posici n de montaje Sw Br Figura 7 Patr n de agujeros para la bomba de circulaci n U 4814 Figura 8 Flujo volum trico y resistencia de paso Bomba de c...

Page 78: ...esultar en el desgaste de la arandela de tope en el rodete Figura 9 Bomba de circulaci n U 4854 Posici n de montaje 5 min 0 90 249 53 31 110 38 225 32 60 99 5 38 23 131 5 Sw Br 0 85 Figura 10 Patr n d...

Page 79: ...8 98 115 60 0 90 0 85 min 5 32 23 224 2 38 38 Figura 13 Patr n de agujeros para la bomba de circulaci n U 4855 Figura 14 Flujo volum trico y resistencia de paso Bomba de circulaci n U 4855 1 1 1 0 0...

Page 80: ...2500 l h resultar en el desgaste de la arandela de tope en el rodete Figura 15 Bomba de circulaci n U 4856 Posici n de montaje 38 38 31 53 126 229 2 23 32 60 115 0 90 0 85 min 5 Figura 16 Patr n de a...

Page 81: ...modo de error despu s de aprox 1 s Si a pesar de estar bajo corriente el motor no realiza una revoluci n completa en el plazo de 1 s igualmente se desconectar a trav s del modo de error 5 5 4 Modo de...

Page 82: ...arte est el modo puramente de conmutaci n y por la otra parte est el modo intermitente En el modo intermitente esta salida sirve para emitir los c digos de error intermitentes a trav s de la indicaci...

Page 83: ...ente s lo se podr n utilizar v lvulas de sobrepresi n con una presi n de apertura de 2 bar como m ximo Antes de la primera puesta en servicio del calefactor o despu s de renovar el l quido refrigerant...

Page 84: ...namiento la temperatura de inflamaci n del combustible diesel Las tuber as deben protegerse contra impactos de piedras El combustible que gotee o que se evapore no debe poder acumularse ni inflamarse...

Page 85: ...e escape La longitud total de la tuber a de aspiraci n de aire de combusti n y la tuber a de gas de escape es de 2 10 m como m ximo Curvaturas m ximas admisibles 270 Dimensiones admisibles para la tub...

Page 86: ...r a m xima admisible 0 60 m sin prolongaci n de aspiraci n de aire de combusti n La longitud total de la tuber a de aspiraci n de aire de combusti n y la tuber a de gas de escape es de 2 10 m como m x...

Page 87: ...ulaci n con F1 25A La l nea para la entrada del interruptor principal debe protegerse con 5A El enchufe contrario a ser utilizado incluyendo los contactos y aislamientos de conductores individuales ne...

Page 88: ...on v lidas para una longitud m xima de conductor de hasta 7 5 m Para longitudes mayores por favor refi rase a la Tabla en la p gina 83 F1 25A F2 5A HS BA HS BA BM UP UP UP DVW MV C P T 3pin 1 2 3 4 1...

Page 89: ...na 86 Protecci n contra sobrecalentamiento 1 2 Unidad de control Cl Cl Cl Cl Cl Cl Calefactor Thermo E opcional Sensor de temperatura del refrigerante Reloj programador 1531 Las secciones transversale...

Page 90: ...el veh culo Power T Sensor de temperatura C1 Interruptor principal T1 sensor de temperatura C2 KL 31 T2 Protecci ncontrasobrecalentamiento C3 Indicaci n de funcionamiento T3 Masa C4 KL 30 V Precalent...

Page 91: ...montar el calefactor se deben purgar minuciosamente el circuito de agua y el sistema de suministro de combustible Para ello es necesario llenar el conducto de aspiraci n y el filtro de combustible del...

Page 92: ...ire de combusti n Bomba de circulaci n Transmisor de la chispa de encendido V lvula magn tica Tiempo en s 12 1 0 15 5 30 90 12 1 0 15 5 30 90 12 1 0 15 5 30 90 Estado Buscar Alimentaci n con consulta...

Page 93: ...r n realizarse de acuerdo a las instrucciones contenidas en el manual de taller INDICACI N Las fundas de manguito enchufable se pueden separar m s f cilmente de la unidad de control si primero se pres...

Page 94: ...r principal HS 2 Reset de la unidad de control nueva inicializaci n de la unidad de control p ej interrumpiendo la alimentaci n de corriente Adicionalmente al bloqueo por error se produce tambi n el b...

Page 95: ...ahora se podr cancelar mediante una nueva interrupci n de la alimentaci n de corriente por 5 s dentro de los 2 min subsiguientes Interrumpir la alimentaci n de corriente p ej Extraer el fusible Separa...

Page 96: ...de temperatura Interrupci n del sensor de temperatura Sensor de temperatura protecci n contra sobrecalentamiento no plausibles Cortocircuito en protecci n contra sobrecalentamiento Interrupci n en la...

Page 97: ...n la placa de caracter sticas del calefactor combustible diesel seg n DIN EN 590 Rigen las limitaciones de uso contenidas en la norma es decir diesel de invierno hasta 20 C y diesel rtico hasta 40 C A...

Page 98: ...mo de agua l h 2400 200 2700 200 Volumen m nimo del circuito de refrigerante l m n 25 0 CO2 en el gas de escape con tensi n nominal en volumen 9 5 0 5 10 0 0 5 0 8 CO2 en el gas de escape con aplicaci...

Page 99: ...ent 6000SC Flujo volum trico I h 5000 contra 0 2 bar 5000 contra 0 2 bar 6000 contra 0 4 bar 6000 contra 0 4 bar Tensi n nominal V 12 o 24 24 24 24 Alcance de la tensi n de servicio V 20 28 20 28 20 2...

Page 100: ...Datos t cnicos Thermo E 200 320 96...

Page 101: ...hien 140 00 Praha 4 Tel 420 2 41045450 7 D nemark DK 2610 R dovre Tel 45 44 522000 Estland 11214 Tallinn Tel 372 651 9309 Lettland 1004 Riga K Ulmana gatve 2 Tel 371 7807873 Litauen 2300 Vilnius Jo io...

Page 102: ...s Papier verwendet Printed in Germany 12 11 Druck Steffendruck Friedland nderungen vorbehalten Subject to modification Sous r serve de modifications Spheros GmbH Spheros GmbH Friedrichshafener Stra e...

Reviews: