Thermo E 200/320
Malfunctions
59
– Remedy the failure cause and then interrupt the power supply for at
least 5 sec. within the next 2 min.
2. Generally
– purge cycle 120s (Attention: Reading the flash code 8, the purge
cycle takes place without burner motor)
– interruption of the power supply
– remedy the failure cause
– return the power supply
– switch the heater on
– Now the heater lock-out can be released if the power supply for at
least 5 sec. within the next 2 min is interrupted again.
Power supply interruption for example by
– remove the fuse
– disconnect the connector "C" at heater
Release 120s possible
Interrupt the power supply 5 sec.
Failure
(HLO)
occurs
Purge cycle done:
Acc. to kind of failure
and occurence time
0
x
x+120
time in sec.
0
x
x+120
time
Release 120s possible
Interrupt the power supply 5 sec.
Failure
occurs
Purge cycle done:
Acc. to kind of failure
and occurence time
U
batt
of
f
U
ba
tt
on
Remedy
failure
MS on
in
sec.