DF/FF MANUAL 118002-001 R
ev B
Consult Spellman’s Sales Department
for details.
1.2.2 SYSTEM STATUS AND
FAULT DIAGNOSTIC
DISPLAY
Dead front type indicators are provided
to give the user indication of system
operation and fault conditions. If a fault
occurs, the power supply will shut
down. To reset, toggle the CONTROL
POWER ON switch, or use the reset
function on remote user interface.
INTERLOCK CLOSED:
Indicates
the EXTERNAL INTERLOCK
connections are in the closed position.
INTERLOCK OPEN:
Indicates the
EXTERNAL INTERLOCK
connections are in the open position.
OVER VOLTAGE:
Indicates the over
voltage protection circuitry has caused
the power supply to turn off. Over
voltage is internally set to 105%-110%
of rated output voltage.
OVER CURRENT:
Indicates the
output current has exceeded 10% of
rated output current. The over current
level is internally set.
OVER POWER:
indicates the output
power has exceeded the front panel or
remote programmed power trip level.
ARC:
Indicates that a tube arc has
occurred.
KV RGLT ERROR:
Indicates that the
high voltage regulation circuit cannot
maintain voltage regulation. This may
occur if the input voltage is too low.
MA RGLT ERROR:
Indicates that the
tube emission current regulation circuit
error cannot maintain current regulation.
This may occur when tube filament
problems exist.
FILAMENT CURRENT LIMIT:
Indicates that filament current has
exceeded the programmed filament
current limit trip level.
KV MIN:
Indicates the minimum KV
level is not being programmed. This
indicator will illuminate for
approximately 10 seconds before shut
down. This provides protection of the
tube filament. The KV min circuitry also
resets the KV and MA/filament ramp
circuits. When the voltage is programmed
higher than the kV min level, the outputs
will begin the ramp cycle.
LEAKAGE LIMIT/TEMP
: On the
DF/FF power supply, a tube leakage
current detection circuit is provided. Shut
down will occur if leakage current
exceeds 5mA. A test point on the rear
panel is also provided for test purposes.
LED LEAKAGE/TEMP will blink at
approximately 0.5Hz frequency.
Temperature is constantly monitored
inside the unit. Shut down will occur if
temperature exceeds safe operating level.
Steady illumination on
LEAKAGE/TEMP front panel LED will
indicate over temperature condition.
OPEN FILAMENT:
Indicates the X-ray
tube filament or connections to the
filament are open.
1.3
OPTIONS:
The options available are listed in Table
1.1. See Section 5 for more information
on these options along with operating and
Summary of Contents for X3645
Page 1: ...DF FF MANUAL 1 118002 001 Rev B ...
Page 2: ...DF FF MANUAL 2 118002 001 Rev B ...
Page 28: ...DF FF MANUAL 118002 001 Rev B ...
Page 29: ...DF FF MANUAL 118002 001 Rev B ...
Page 30: ...DF FF MANUAL 118002 001 Rev B ...
Page 31: ...DF FF MANUAL 118002 001 Rev B ...
Page 32: ...DF FF MANUAL 118002 001 Rev B ...
Page 33: ...DF FF MANUAL 118002 001 Rev B ...
Page 34: ...DF FF MANUAL 118002 001 Rev B ...
Page 35: ...DF FF MANUAL 118002 001 Rev B ...
Page 36: ...DF FF MANUAL 118002 001 Rev B ...
Page 37: ...DF FF MANUAL 118002 001 Rev B ...
Page 38: ...DF FF MANUAL 118002 001 Rev B ...
Page 39: ...DF FF MANUAL 118002 001 Rev B ...
Page 40: ...DF FF MANUAL 118002 001 Rev B ...