118142-001 Rev B
Page 75 of 104
6.4 COMMAND OVERVIEW
Data Byte section of the TCP/IP Datagram
Command Name
<CMD>
<ARG>
RANGE
Program RS-232
unit baud rate
07
1 ASCII
1 - 5
Program kV
10
1-4 ASCII
0-4095
Program mA
11
1-4 ASCII
0-4095
Program Filament
Limit
12
1-4 ASCII
0-4095
Program Filament
Pre-Heat
13
1-4 ASCII
0-4095
Request kV
Setpoint
14
None
-
Request mA
Setpoint
15
None
-
Request Filament
Limit Setpoint
16
None
-
Request Filament
Pre-Heat Setpoint
17
None
-
Request Analog
Monitor
Readbacks
19
None
-
Request HV On
Hours Counter
21
None
-
Request Status
22
None
-
Request Software
Version
23
None
-
Request Hardware
Version
24
None
-
Request Web
Server Version
25
None
-
Request Model
Number
26
None
-
Reset HV On
Hours Counter
30
None
-
Reset Faults
31
None
-
Program Power
Limit
47
1-4 ASCII
0-1200
Request Power
Limit Setpoint
48
None
-
Read Interlock
Status
55
None
-
Request kV
monitor
60
None
-