1-800-348-5004

6. For positive-grounded vehicle, connect NEGATIVE (BLACK) clip from battery charger to NEGATIVE (NEG, N, –) 

    ungrounded post of battery. Connect POSITIVE (RED) clip to vehicle chassis or engine block away from battery. 

    Do not connect clip to carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gauge metal part of the 

    frame or engine block.

7. Set Battery Type switch according to battery type:

    • Set to Regular for flooded and maintenance-free batteries.  

    • Set to AGM for Absorbed Glass Mat batteries.

8. Set Setting switch to desired charge amperage.

9. After switches are set, plug in charger.

10. Monitor the charging process. The Charge Complete indicator will light up and blink when the battery is fully charged.

11. When disconnecting charger, disconnect AC cord, remove clip from vehicle chassis, and then remove clip from 

      battery terminal.

12. After use clean, then store the charger indoors out of children’s reach.

Note:

 If the charger cycles between maximum charge level and a lower charge level when first connected, then the 

battery may be fully charged or nearly fully charged.  Further charging may not be needed.  If charging is attempted, 

charge at a lower rate and carefully monitor charge level to avoid battery damage.

WARNING!  TO PREVENT EXPLOSION: DO NOT USE WITH GEL BATTERIES.

Charging Battery Outside Vehicle

WARNING: A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION.  TO REDUCE RISK OF A SPARK 
NEAR BATTERY FOLLOW THESE INSTRUCTIONS EXACTLY.

NOTICE:  If the Reverse Connection indicator lights, the cables are connected improperly. Immediately 
disconnect the cables and connect them properly to prevent damage to the battery.

WARNING!  TO PREVENT EXPLOSION: DO NOT USE WITH GEL BATTERIES.

1. Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually has a larger diameter than NEGATIVE 

    (NEG, N, –) post.

2. Attach at least a 24-inch-long 6-gauge (AWG) insulated battery cable to NEGATIVE (NEG, N, –) battery post.

3. Connect POSITIVE (RED) charger clip to POSITIVE (POS, P, +) post of battery.

4. Position yourself and free end of cable as far away from battery as possible – then connect NEGATIVE (BLACK) 

    charger clip to free end of cable.

5. Do not face battery when making final connection.

6. Set Battery Type switch according to battery type:

    • Set to Regular for flooded and maintenance-free batteries.

    • Set to AGM for Absorbed Glass Mat batteries.

7. Set Setting switch to desired charge amperage.

8. After switches are set, plug in charger.

9. Monitor the charging process. The Charge Complete indicator will light up and blink when the battery is fully charged.

10. When disconnecting charger, always do so in reverse sequence of connecting procedure and break first connection 

      while as far away from battery as practical.

11. After use clean, then store the charger indoors out of children’s reach.

12V Engine Starting

NOTICE: Some vehicles with onboard computers may be damaged from the high-current starting output.   
Thoroughly read the vehicle service manual before using this procedure.
Note: 

During extremely cold weather or when battery is severely exhausted, charge the battery for about five minutes 

before attempting to turn on engine.
1. Unplug the Charger AC power cord from the AC outlet.

2. For negative-grounded vehicle, connect POSITIVE (RED) clip from battery charger to POSITIVE (POS, P, +) 

    ungrounded post of battery. Connect NEGATIVE (BLACK) clip to vehicle chassis or engine block away from battery. 

    Do not connect clip to carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gauge metal part of the

    frame or engine block.

Summary of Contents for 07215

Page 1: ...emble maintain install or operate this product Observe all safety information to protect yourself and others Failure to observe the instructions may result in property damage and or personal injury Please keep instructions for future reference For warranty purchases please keep your dated proof of purchase File or attach to the manual for safe keeping For Customer Service Call 1 800 348 5004 or e ...

Page 2: ...ating of charger 6 Do not operate this charger with a damaged cord or plug Replace the cord or plug immediately 7 Do not operate charger if it has received a sharp blow been dropped or otherwise when service or repair is required Incorrect reassembly may result in a ri 9 To reduce risk of electric shock unplug charger from outlet before attempting any maintenance or cleaning Recommended minimum AW...

Page 3: ...gs on these products and on engine 11 Personal Precautions a Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes c Wear complete eye protection and clothing protection Avoid touching eyes while working near battery d If battery acid co...

Page 4: ...disconnect the charging clamps Immediately ventilate the room by opening windows and doors Do not switch on an electrical fan When the air has cleared of gas unplug the unit from the electrical outlet b Charge the battery in a well ventilated area c To prevent sparking due to electrostatic discharge never wear clothes made of synthetic materials when charging the battery ignite the gasses caused b...

Page 5: ...CHARGED BATTERY Initial charge current to the battery is at the maximum FIGURE C BATTERY ALMOST FULLY CHARGED Charge current to the battery is reduced Figure D FULLY CHARGED BATTERY Charge current to the battery is minimal and the green LED is on Charging Floating WARNING TO PREVENT SERIOUS INJURY DO NOT PLUG IN CHARGER UNTIL DIRECTED TO DO SO Sometimes conditions such as a cold battery a sulfated...

Page 6: ...er 5 10 minutes needle does not move off high end the battery probably has a short circuit Unplug charger and discontinue use Have battery checked by a qualified technician COLD BATTERIES begin charging at a low rate increase as battery reaches a normal temperature then rate will decrease normally DO NOT CHARGE A FROZEN BATTERY BATTERIES WITH HYDROMETER EYE Do not depend on hydrometer eye to deter...

Page 7: ...ARNING TO PREVENT EXPLOSION DO NOT USE WITH GEL BATTERIES 1 Check polarity of battery posts POSITIVE POS P battery post usually has a larger diameter than NEGATIVE NEG N post 2 Attach at least a 24 inch long 6 gauge AWG insulated battery cable to NEGATIVE NEG N battery post 3 Connect POSITIVE RED charger clip to POSITIVE POS P post of battery 4 Position yourself and free end of cable as far away f...

Page 8: ...damaged equipment If abnormal noise or vibration occurs have the problem corrected before further use Maintenance Instructions Troubleshooting Problem Possible Causes Likely Solutions Charger will not start 1 Cord not connected 2 No power at outlet 3 Clamps are not securely connected to battery terminals 1 Check that cord is plugged in 2 Check power at outlet If outlet is unpowered turn off charge...

Page 9: ...alterations or a lack of maintenance FOT shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To receive service under warranty the original manufacturer part must be returned for examination by an authorized service center Shipping and handling charges may apply If a defect is found FOT will e...

Reviews: