background image

[email protected]

4

1-800-348-5004

Note: Amperage is only present when the unit 

is connected to a battery or in START mode.

 Input

120V

~. 

60 Hz 

Output

   12 VDC - 10*A

   12 VDC - 2*A

 Engine Start - 50 A

16. Use this Battery Charger with flooded lead-acid or AGM batteries only. When  

      charging a maintenance-free battery, always monitor the  progress of the charge

      by viewing the ammeter. Do not over charge a maintenance-free battery.

17. Do not attempt to charge non-rechargeable or defective batteries.

18. Never simultaneously charge several batteries.

19. Do not discard used batteries in the trash. Properly recycle according to local 

      environmental codes.

20. 

WARNING: 

People with pacemakers should consult their physician(s) before 

   r

e

k

a

m

e

c

a

p

 t

r

a

e

h

 

a

 

o

y

ti

      could cause interference to or failure of the pacemaker.

21. 

Risk of Explosion!

     a. lf you detect gas, do not adjust any switches. Do not disconnect the charging 

         clamps. Immediately ventilate the room by opening windows and doors. Do not 

         switch on an electrical fan. When the air has cleared of gas, unplug the unit 

         from the electrical outlet.     

     b. Charge the battery in a well-ventilated area.     

     c. To prevent sparking due to electrostatic discharge, never wear clothes made of 

         synthetic materials when charging the battery.    

         ignite the gasses caused by charging and cause an explosion.

d

Grounding and AC power cord connection instructions

  

Charger should be grounded to reduce risk of electric shock. Charger is equipped with 

an electric cord having an equipment-grounding conductor and a grounding plug. 

     

n

d

e

d

n

u

o

r

g

 

d

n

a

 

d

e

ll

a

t

s

n

y

lr

e

p

o

r

p

 

s

t

a

h

t

e

lt

u

o

 

n

a

 

o

t

n

d

e

g

g

u

l

p

 

e

b

 t

s

u

m

 

g

u

l

p

 

e

h

T

accordance with all local codes and ordinances.

Danger:

 Never alter AC cord or plug provided

 

oper connection can result in a 

               risk of an electric shock.

Caution

: Risk of Fire or Electric Shock. Connect battery charger directly to grounding 

               receptacle (three-prong). An adapter should not be used with battery charger. 

Summary of Contents for 07215

Page 1: ...emble maintain install or operate this product Observe all safety information to protect yourself and others Failure to observe the instructions may result in property damage and or personal injury Please keep instructions for future reference For warranty purchases please keep your dated proof of purchase File or attach to the manual for safe keeping For Customer Service Call 1 800 348 5004 or e ...

Page 2: ...ating of charger 6 Do not operate this charger with a damaged cord or plug Replace the cord or plug immediately 7 Do not operate charger if it has received a sharp blow been dropped or otherwise when service or repair is required Incorrect reassembly may result in a ri 9 To reduce risk of electric shock unplug charger from outlet before attempting any maintenance or cleaning Recommended minimum AW...

Page 3: ...gs on these products and on engine 11 Personal Precautions a Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes c Wear complete eye protection and clothing protection Avoid touching eyes while working near battery d If battery acid co...

Page 4: ...disconnect the charging clamps Immediately ventilate the room by opening windows and doors Do not switch on an electrical fan When the air has cleared of gas unplug the unit from the electrical outlet b Charge the battery in a well ventilated area c To prevent sparking due to electrostatic discharge never wear clothes made of synthetic materials when charging the battery ignite the gasses caused b...

Page 5: ...CHARGED BATTERY Initial charge current to the battery is at the maximum FIGURE C BATTERY ALMOST FULLY CHARGED Charge current to the battery is reduced Figure D FULLY CHARGED BATTERY Charge current to the battery is minimal and the green LED is on Charging Floating WARNING TO PREVENT SERIOUS INJURY DO NOT PLUG IN CHARGER UNTIL DIRECTED TO DO SO Sometimes conditions such as a cold battery a sulfated...

Page 6: ...er 5 10 minutes needle does not move off high end the battery probably has a short circuit Unplug charger and discontinue use Have battery checked by a qualified technician COLD BATTERIES begin charging at a low rate increase as battery reaches a normal temperature then rate will decrease normally DO NOT CHARGE A FROZEN BATTERY BATTERIES WITH HYDROMETER EYE Do not depend on hydrometer eye to deter...

Page 7: ...ARNING TO PREVENT EXPLOSION DO NOT USE WITH GEL BATTERIES 1 Check polarity of battery posts POSITIVE POS P battery post usually has a larger diameter than NEGATIVE NEG N post 2 Attach at least a 24 inch long 6 gauge AWG insulated battery cable to NEGATIVE NEG N battery post 3 Connect POSITIVE RED charger clip to POSITIVE POS P post of battery 4 Position yourself and free end of cable as far away f...

Page 8: ...damaged equipment If abnormal noise or vibration occurs have the problem corrected before further use Maintenance Instructions Troubleshooting Problem Possible Causes Likely Solutions Charger will not start 1 Cord not connected 2 No power at outlet 3 Clamps are not securely connected to battery terminals 1 Check that cord is plugged in 2 Check power at outlet If outlet is unpowered turn off charge...

Page 9: ...alterations or a lack of maintenance FOT shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To receive service under warranty the original manufacturer part must be returned for examination by an authorized service center Shipping and handling charges may apply If a defect is found FOT will e...

Reviews: