background image

 

 

 

   Worldwide Distribution 

 

France 

Eurolabo - Paris. 
Tel.01 42 08 01 28 
Fax 01 42 08 13 65 
email: [email protected] 
 

Germany  

L.O.T. - Oriel GmbH & Co, 
KG - Darmstadt 
Tel: 06151 88060 
Fax: 06151 880689 
email:[email protected] 
Website: www.LOT-Oriel.com/de 

 
Japan  

Systems Engineering Inc. -Tokyo 
Tel: 03 3946 4993 
Fax: 03 3946 4983 
email:[email protected] 
Website: www.systems-eng.co.jp 

 
Spain  

Teknokroma S.Coop C. Ltda 
Barcelona 
Tel: 93 674 8800 
Fax: 93 675 2405 
email: [email protected]

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Switzerland 

Portmann InstrumentsAG  
Biel-Benken 
Tel: 061 726 6555 
Fax: 061 726 6550 
email: [email protected] 
Website:www.portmann-instruments.ch 

 
USA 

SPECAC INC. 
414 Commerce Drive 
Suite 175,  
Fort Washington, 
PA 19034, USA 
Tel: 215 793 4044 
Fax: 215 793 4011 
 

United Kingdom 

Specac Ltd. - London

 

River House, 97 Cray Avenue, 
Orpington 
Kent BR5 4HE 
Tel: +44 (0) 1689 873134 
Fax: +44 (0) 1689 878527 
Registered No. 1008689 England

Summary of Contents for Atlas Lightweight Evacuable Pellet Die

Page 1: ...Atlas Lightweight Evacuable Pellet Dies User Manual 2I 25410 Issue 3...

Page 2: ......

Page 3: ...Atlas Lightweight Evacuable Pellet Dies User Manual 2I 25410 Issue 3...

Page 4: ...5 FILLING THE DIE WITH SAMPLE 11 6 MAKING THE PELLET 12 7 REMOVING THE PELLET FROM THE DIE 13 8 CLEANING AND STORAGE OF THE DIE 14 9 LEGEND FOR THE LIGHTWEIGHT DIE 14 10 SPARE PARTS FOR THE LIGHTWEIGH...

Page 5: ...greatly reduced as the Dies themselves are physically smaller and lighter in weight by comparison to conventional 32mm and 40mm diameter pellet dies To aid in the weight reduction there are no individ...

Page 6: ...the Atlas Lightweight Evacuable Pellet Die from its protective packaging Please check that the following have been supplied A 32mm or 40mm Lightweight Evacuable Pellet Die complete To include the fol...

Page 7: ...Atlas Lightweight Evacuable Pellet Dies 7 O ring for Plunger Extractor cap Check the parts over and proceed to use them from the following instructions...

Page 8: ...Atlas Lightweight Dies are made from corrosion resistant steel 440C but because of the nature of certain materials that may be used with the Dies it is necessary to take certain precautions Any sampl...

Page 9: ...rasive cleaning cloths on the polished faces of the plunger 1 and the base 2 2 Place the base 2 onto the bench top Ensure the base O ring seal 3 is correctly positioned in the groove on the base 2 and...

Page 10: ...User Manual 10 Exploded Diagram of Atlas Lightweight Evacuable Pellet Die 5 1 4 6 3 2...

Page 11: ...been placed into the cylinder body 4 use the tip of a spatula to spread the powder such that it has a flat evenly distributed surface Preparation of the uncompacted powder surface helps to produce a...

Page 12: ...ample or set of samples to be compressed If using a vacuum apply evacuation to the Die assembly prior to compression in the Press Note Evacuation of the Die assembly can help in the production quality...

Page 13: ...end of the extractor cap 7 onto the underside of the cylinder body 4 This configuration of parts creates a space for the compacted pellet to be pushed into after further travel of the plunger 1 3 Pla...

Page 14: ...by a combination of washing with warm water then distilled water and finally with methanol The Die parts are then dried and can be stored in a desiccator warming cabinet or left on a warm 35 C hot pl...

Page 15: ...5412 Atlas 32mm Lightweight Die Body P N GS25413 Atlas 32mm Lightweight Die Plunger P N GS25414 Atlas 32mm Lightweight Die Base P N GS25415 Atlas 32mm Lightweight Die O ring Kit P N GS25416 Atlas 40mm...

Page 16: ...User Manual 16 Notes...

Page 17: ...bsite www systems eng co jp Spain Teknokroma S Coop C Ltda Barcelona Tel 93 674 8800 Fax 93 675 2405 email comercial teknokroma es Switzerland Portmann InstrumentsAG Biel Benken Tel 061 726 6555 Fax 0...

Page 18: ...SPECAC INC 414 Commerce Drive Suite 175 Fort Washington PA 19034 USA Tel 215 793 4044 Fax 215 793 4011 SPECAC LTD River House 97 Cray Avenue Orpington Kent BR5 4HE Tel 44 0 1689 873134 Fax 44 0 1689...