Troubleshooting
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE ACTION
No Power
POWER ON/OFF button
Turn system on using power switch
has not been switched
Battery may be run down
Charge battery or operate PROvision on 110/220V AC
Check battery fuse (near external reel connector)
No Power with AC
AC outlet is not powered
Test outlet for proper current
power cord connected
AC power cord has failed
Test unit using alternative power cord
AC power cord fuse may be
Check the integrity of the fuse.
blown
(See page 14 for location)
The power unit may have failed
Contact Spartan Tool Customer Service
at (800) 435-3866. NEVER ATTEMPT
TO REPAIR THE POWER UNIT ON
THE PROVISION
Picture is dim or hard
The light intensity adjustment
Use the intensity slide bar to increase the
to see
may be too low
light intensity
Will not record
Thumbdrive not installed or not
fully inserted
Insert thumbdrive
Thumbdrive has reach full
capacity
Delete Un-wanted Files