Form No. 43539049
–10–
Oct 2013
4F.
ELECTRODE AND CABLE ASSEMBLY (DSI Models 5B and 5D Only)
1. Fasten the electrode holder bracket assembly to the support brace using two (2) #10-24 screws and nuts.
See Figure 6d. NOTE: The electrode holder bracket is attached to the support brace located in-line with
the control arm tubing.
2. Place the electrode (spark igniter) onto the holder bracket and secure using two (2) #8-32 screws and
nuts. See Figure 6d.
3. Slide the ignition cable quick connect terminal over the electrode until it snaps in place.
4G. GAS VALVE WIRE CONNECTIONS
1.
DSI Models 5B and 5D: Locate the two (2) blue wires from the ignition control assembly (control no. 5B
and 5D only). Connect these to the valve terminals shown in Figure 6e. Refer to the wiring diagram
location in Section 8,
Electrical Connections.
2.
Pilot Models 2A and 2B: Connect the 24V supply wires (field supplied) to the gas valve of control no. 2A
and 2B. See Figure 6e.
FIGURE 6e
FIGURE 6d